43
6. CONTROL
CHANGE
7. SYSTEM
EXCLUSIVE
This determines whether the QX5 will record Continuous Control Changes (control
numbers
0-63)
such as Modulation
Wheel,
Foot Controller,
Breath
Controller,
Volume, Portamento Time and Data Entry Slider. (See the list of Control changes
on p. 22.)
6>CONTROL
CHNG
ON
This determines whether the QX5 will receive and record System Exclusive mes-
sages.
7>SYS.
EXCLUSIVE
ON
System Exclusive messages will be recorded in the same way as Note and Controller
messages. This means that if Sys.Exclusive is on, you can record Voice Parameter
changes (such as EG Rate or Algorithm) sent from a KX88.
NOTE
System Exclusive messages beginning with "FO, 43, On..." or "FO, 43, 1n..."
or "FO, 43, 2n ..." are for the QX5 itself (bulk sequence memory). They will
be loaded into QX5 sequence memory if the Device Number "n" matches the
QX5 device number (p. 44). If the QX5 device number is OFF, all System
Exclusive messages will be recorded in the usual way.
D