9. Lift plate out of the aeration plate top.
10. Install new french plate by reversing steps 1-9.
REMOVAL OF HIGH SPEED ELEMENTS
1. Remove the back riser.
2. Flip over aeration plate to expose the element terminal ends and wiring.
3. Note and disconnect all element connector and grounding wire(s). (Fig. 24)
4.
Snap the element out of the ring/bowel assembly. (Fig 25)
WIRE CONNECTION POINTS
Fig. 24
Fig. 25
20