Commissioning
7.4 System settings
5. Correct the values in the "Horizontal resolution" input field until the right internal border of
the gray/blue area is pixel-exact at the right edge of the SMPTE image.
6. Use the "Vertical blank pixels" input field to shift the top edge of the SMPTE image pixel-
exact to the top internal border of the gray/blue area.
Note
Gray/blue area not visible
If no gray/blue area is visible on the top and bottom sides of the image, reduce the
"Vertical resolution" until the gray/blue area becomes visible.
7. Correct the values in the "Vertical resolution" input field until the bottom internal border of
the gray/blue area is pixel-exact at the bottom edge of the SMPTE image.
8. Execute the "Force"
Timing successfully set
The unknown timing has been successfully set, you can now exit the OSD menu. The
display will recognize the newly set timing and set it as saved whenever connected in the
future.
Note
New timings need only be learned and saved once. The display subsequently recognizes the
timings automatically.
The desired zoom factor can be selected in "Live mode" when all settings have been
completed.
Once all settings have been carried out in Force Mode, the desired zoom factor can be
selected from the "Position/Zoom" menu.
Further use of determined values
The values determined step-by-step using "Live mode" can now be copied and entered
directly in further displays using "Blind mode".