Eizo SCD 19102 Instruction Manual page 61

High-end 19" color and gray scale flat panel display
Hide thumbs Also See for SCD 19102:
Table of Contents

Advertisement

Servicelevel 2
Force Mode
Temperature
SCD 19102 / SMD 19102
Instruction Manual, 10/2011, A5E01588521A-004
Function
Blind mode
Live mode
Help
Temperature limit
Shutdown temperature
For SCD 19102:
Operation time above 160 cd
For SMD 19102:
Operation time above 400 cd
For SCD 19102:
Operation time below 160 cd
For SMD 19102:
Operation time below 400 cd
Adjustment/range
Execute
Execute
Execute
25 °C ... 90 °C
Default: 60 °C
25 °C ... 90 °C
Default: 70 °C
Information
Information
Commissioning
7.3 Description of OSD menu
Description
Force Mode is a tool for
setting unknown timings that
are not displayed via exact
modes that have already
been stored.
Suitable for the direct input
of previously determined
Force Mode data.
Note:
See the section "Display
adjustment - Force Mode"
(Page 65)
Force Mode is a tool for
setting unknown timings that
are not displayed via Exact
Modes that have already
been stored.
Suitable for step-by-step
setting of an unknown timing
or for fine adjustment of a
timing whose data have
been entered using "Blind
mode".
Note:
See the section "Display
adjustment - Force Mode"
(Page 65)
Brief description of the
Force Mode functions
The temperature can be
selected here above which
the display is dimmed
The temperature can be
selected here above which
the display is switched off
Display operating hours
counter over 160 Cd/m² for
SCD 19102 and 400 Cd/m²
for SMD19102
Display operating hours
counter below 160 Cd/m² for
SCD 19102 and 400 Cd/m²
for SMD19102
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smd 19102

Table of Contents