Lens and filter inside lens mount on body

l Be sure that there is no dirt on surface of lens and filter inside lens mount on body before measurement.
Correct measurement result cannot be obtained if dirt, dust or handsoil is left or uncleaned.
l Do not touch surface of lens and filter inside lens mount on body with hand.
l Lens and filter inside lens mount on body could become fogged up if ambient temperature fluctuates under
high humidity. Be careful not to generate such condition for correct measurement cannot be performed.

Storage

Body

l Cover lens mount with standard accessory mount cover in storing lens in removed state.
l Do not store this instrument under direct sunlight or near heater. The internal temperature of this
instrument could become much higher than ambient temperature which may break this instrument.
l Store this instrument at ambient temperature between 0ºC and 30ºC and relative humidity 70% or less
with no condensation or between 30ºC and 35ºC and relative humidity 55% or less with no condensation.
Storage under high temperature and humidity may deteriorate performance of this instrument. For added
safety, we recommend storage with a drying agent at room temperature.
l Even if the product is stored within the specified storage temperature/humidity range, the displayed values
may be affected by long-term conditions of storage. If you have any question about specification, please
contact the nearest Konica Minolta-authorized service facility.
l Take care not to form condensation. Avoid rapid change in ambient temperature when transferring body
for storage.
l Put body in packaging box supplied when purchased or optional soft case (CA-A60) to store in safe place.

Lens

l Cover lens with lens cap, or lens hood with hood cap for storage.
l When you remove lens from body for storage, cover lens with lens cap and mount cap.
Temperature/Humidity conditions under which the instrument is used and stored
It is recommended that the instrument be used and stored under standard conditions (Temperature: 23ºC; Relative
humidity: 40%), and that areas subject to high temperature and/or humidity be avoided. In addition in order to maintain the
measurement accuracy of this instrument, it is recommenced that it be inspected regularly about once a year. For details
on having the instrument inspected, please contact the nearest Konica Minolta-authorized service facility.
Even if the product is used within the specified operating temperature/humidity range or stored within the specified
storage temperature/humidity range, the displayed values may be affected by long-term conditions of use or storage.
If the instrument is left under the following high-temperature conditions for a long period of time, the displayed values may
change as follows:
Temperature: 30ºC; Relative humidity: 70%; Period under these conditions: 720 hours (30 days)
Accuracy: Luminance: ±0.4 %; Chromaticity: ±0.003
Inter-point error: Luminance: ±0.2 %; Chromaticity: ±0.0003
Temperature: 35ºC; Relative humidity: 55%; Period under these conditions: 336 hours (14 days)
Accuracy: Luminance: ±1 %; Chromaticity: ±0.006
Inter-point error: Luminance: ±0.5 %; Chromaticity: ±0.001
These differences in display values are due to the instrument materials and/or components being affected by the
temperature and humidity conditions of long-term use or storage. In particular, optical filters are easily affected by
temperature or humidity. Although measures have been taken to improve resistance to temperature/humidity changes, the
accumulated effect of long-term use or storage may affect the displayed values.
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ca-2500sCa-2500wCa-2500t

Table of Contents