Konica Minolta CA-2500 Series Instruction Manual page 33

2d color analyzer
Table of Contents

Advertisement

*1: Error in angle of view: 7%
*2: Measurement time differs depending on brightness of measurement object, PC performance, and data processing contents.
The specifications above were obtained under Konica Minolta's measurement conditions shown below:
PC CPU
: Intel
Core™ i7-3770 3.40 GHz
®
Memory
: 8 GB
Data processing
: Pseudocolor display of luminance data
Resolution
: 980 x 980
Shutter speed
: Y measurement : 1/64 sec., XZ measurement : 1/32 sec.
Measurement subject brightness:
Standard/wide lens: Approx. 80 cd/m
Low-magnification macro ring and telephoto lens: Approx. 400 cd/m
High-magnification macro ring and telephoto lens: Approx. 600 cd/m
* The measurement time becomes longer when the object is dark. The longest measurement time is approx. 14 seconds with 1-time
integration, approx. 45 seconds with 4-time integration, approx. 3 minutes with 16-time integration, approx. 11 minutes with 64-
time integration and approx. 44 minutes with 256-time integration
*3: The specifications above were obtained under Konica Minolta's measurement conditions shown below:
Measurement subject brightness:
Standard/wide lens: Approx. 35 cd/m
Low-magnification macro ring and telephoto lens: Approx. 250 cd/m
High-magnification macro ring and telephoto lens: Approx. 250 cd/m
Distance
: Minimum distance of each lens
Evaluation
: Based on the average obtained within 10% range at the center of the screen
Temperature
: 23°C±2°C
Relative humidity
: 40%±10%
Measuring light
: White, reference light source
Integration
: 64 times (Normal mode)
*4: The specifications above were obtained under Konica Minolta's measurement conditions shown below:
Resolution
: 196 x 196
Shutter speed
: Y measurement: 1/64 sec., XZ measurement: 1/32 sec.
Gain
: Normal (x1),
Light intensity level : Midpoint of appropriate light intensity range
Evaluation
: Based on the maximum repeatability (2 ) of all pixels
Temperature
: 23°C±2°C
Relative humidity : 40%±10%
Measurement subject : White, reference light source
Integration
: 64 times (Normal mode)
*5: The specifications above were obtained under Konica Minolta's measurement conditions shown below:
Measurement subject brightness:
Standard/wide lens: Approx. 40 cd/m
Low-magnification macro ring and telephoto lens: Approx. 200 cd/m
High-magnification macro ring and telephoto lens: Approx. 350 cd/m
Distance
: Calibration distance of each lens
Resolution
: 196 x 196
Evaluation (*6)
: Based on the maximum/minimum values obtained in a square at the center of the screen measuring 60% of the height
and width of the entire screen
(*7)
: Based on the maximum/minimum values obtained in the entire screen
Temperature
: 23°C±2°C
Relative humidity
: 40%±10%
Measurement subject : White, reference light source
Integration
: 64 times (Normal mode)
*8: Even if the instrument is stored within the specified usage (or storage) temperature humidity range, the displayed value may
change depending on long-period usage or storage conditions.
• Windows
, Excel
and Word
are registered trademarks or a trademarks of Microsoft Corporation in the United States and other countries.
®
®
®
• Intel
and Pentium
are a registered trademarks or trademarks of Intel Corporation in the United States and other countries.
®
®
• The specifications and drawings given here are subject to change without prior notice.
• For specification, please contact your nearest Konica Minolta sales office or dealer.