Olympus OM-1 Repair Manual page 79

Hide thumbs Also See for OM-1:
Table of Contents

Advertisement

D-13
7)
Remove two PUK1.7 x 7.5SO on CA8951 (Fastener).
Then comes off CA8.5&1.
8)
Remove four PSKI.4 x 2SO on CA8876 (Cover).
Then comes off CA8876.
Caution:
Two to four pieces of CA8960 (Lever) is used for room
adjustment.
CA8960 is to be placed as shown below by arrows.
A number of them may be set as necessary to adjust
the room between CA8876 (Cover) and CA8878.
9) Remove CA8944 String from adhered part of CA8980 (Pulley).
Then
comes off CA8880 (Gear).
In case of such a type of repair that will
require removal of CA8944 adhered to CA8980 (Pulley) only and not
that of CA887T, CA8878, and CA8880, it is advisable to take
following measures so as to insure that the CA8944 will not be
entangled or become off position.
Set the shutter at the speed of "B" and do not move it.
Stick one end of the CA8944 into the CA8702 (Plate).
Be careful not to cut the string at where it is stuck in.