Olympus OM-1 Repair Manual page 52

Hide thumbs Also See for OM-1:
Table of Contents

Advertisement

05
Major Check
Point_
Relative Function
to be checked
Checking Method or
_Points of Special Attention_
•v
Upon closure of the rear cover and
completion of charging (or even without
charging) the first figure ("1") should
appear in the window after advance¬
ment of 3 frames.
After opening and closure of the
rear cover, the "S'1 should not be
out of position against the index
point any more than the figure width.
At "1" and even numbers, the
center of the index point should be
within 0.2 from the center of the
figure width.
0.2
iT1®
'
0.2
(8) Sound of
the shutter
or mirror
actions
and shocks
4.
ASA Dial
(CA9007)
At odd numbers other than "1",
the center of the index should be
as illustrated.
During the feeling test,it should not
give unusual sound or shocks.
When the locking button is pressed,
it can be moved in either direction
smoothly and accurately to be set at
the desired ASA value.
Olympus.