Olympus OM-1 Repair Manual page 63

Hide thumbs Also See for OM-1:
Table of Contents

Advertisement

C-16
8.
Accuracy of Meter Indications:
LSBL7 Light Source Box
K=1.3
ASA100
BV
SS
F
Discrepancy
Accurac
15
1/500
8
0.3EV
±0.6EV
12
1/125
5.6
+0.6EV
9
1/4
11
+0.6EV
6
1/2
4
0.3EV
±0.6EV
For BV15 and BV6, check the discrepancy in indications which may occur
according to the direction of rotations of the aperture ring and the
shutter dial.
In case of BV12 and BV9, the shutter dial is turned and set starting from
the 1/1000 side and the aperture ring from the F16 side.
LSBL1 Light Source Box
K=1.3
ASA100
(90V)
BV
SS
F
Discrepancy
Accuracy
16
1/500
11
0.3EV
±0.6EV
14
1/125
11
tl
12
1/125
5.6
•1
10
1/125
2.8
II
8
1/2
11
II
6
1/2
5.6
0.3EV
II
For BV16 and BV6, check the discrepancy in indications which may occur
according to the direction of rotations of the aperture ring and the
shutter dial.
In cases of EV 14, 12, 10 and 8, the shutter dial is turned and set starting
from the 1/1000 side and the aperture ring from the F16 side.
p://olvmpus.d lementi a.ore/H