Olympus OM-1 Repair Manual page 53

Hide thumbs Also See for OM-1:
Table of Contents

Advertisement

C-6
Major Check
Relative Function
Checking Method or
Point
to be checked
Points of Special Attention
2)
When the locking button is not
pressed, the A dial would not rotate.
3)
The locking button should not go down
CA9083 (Holder) and come off position.
4)
The tip of the index should be in
line with the edge of the letters
(figure).
I
5)
Upon shifts of the ASA value,the
exposure meter should give different
values appropriately.
The S lever should be operated
lightly, smoothly and accurately and
be click-stopped. (Without extremely
uneven movement, or stoppages.)
Clicking should be felt.
Even if it goes beyond, it should
return to the clicking position.
When the lever is click-stopped,
the ON or OFF letters should be
conspicuous and not hidden
underneath the lever.
By operation of the S lever, the
meter should be turned ON or OFF
accurately.
The needle should not be stuck or
tremble.
5.
Exposure
Meter
Switch
Lever
(CA8962)
1
)
2
)
3)
(1)
Exposure
1)
Meter
Operation
2
)