Olympus OM-1 Repair Manual page 78

Hide thumbs Also See for OM-1:
Table of Contents

Advertisement

D-12
4)
Remove two PUK2 x 3.5SO and PUK2 x 6SO on CA8961 (Frame).
Then come off CA8961 and the exposure meter mechanism in a
unit.
5)
Remove three CA9008 (Screw) to separate CA8980 (Pulley) from
CA8961 (Frame).
The position of the exposure meter mechanism may
be adjusted by loosening CA9008 (Screw).
(Coarse adjustment)
The position of CA8980:
The groove of CA8980 is to be positioned at the shutter
speed 1/1000.
It should be positioned within the range shown below
when CA8879 (Ring) is at the stopper.
6) Remove three CA8947 (Screw). .
Then will come off:
CA8877
(Mount)
CA8888
(Spring)
CA9114
(Screw)
CA8878
(Dial)
CA8947 is to be tightened from the top in order.