Olympus OM-1 Repair Manual page 162

Hide thumbs Also See for OM-1:
Table of Contents

Advertisement

G-7
Use for Check of positions of
connecting ring (CA8879), connecting
lever (CA8425) and Mirror releasing.
How to use;
Mount KC-0074G and B mount by according index of
KC-0074G outer circuit and that of B mount (Shutter
speed setting position).
How to check;
1.
Position of Connecting ring (CA8879)
Pull down A towards you and chek if scratched
line of A returns between two scratched line
of B.
http://oly mpus.demcntia.org/Hardware