E-14
Checkup
o
When the Rear Cover is closed, (8790) should not supple.
o
Even is 8793 is shaken vertically, 8793 should be engaged with
(8790) at least for its own thickness.
o
The tip of (8790) should be lower than the upper surface of 8793.
o
At the commence of motion, (8785) should work on the 4th tooth of
8793.
5)
Adjustment of CA8802 (Pin)
Adjust the E pin like that 8793 will be travelled by 1.2 - 1.8 teeth
space by means of (8785).
When there is insufficient travel, adjust (8802) in the A direction shown
above, and when excessive in the B direction.
Upon adjustment of (8802) realign 8778 and (8790).
The three points explained above, i.e. the positions of 8778, (8790),
and (8802), are all related to the movement of the Film Counter Plate.
6)
CA8795 (Spring) entangled
Check the relative part and adjust.