Fuel Filter Replacement - Kohler KDI 2504TM Workshop Manual

Hide thumbs Also See for KDI 2504TM:
Table of Contents

Advertisement

6
5. Insert and tighten the cartridge support H on the filter
support E (tightening torque at 25 Nm).
6. Fit the pipes B on the support E and secure the pipes B
with the clamps A.

6.7 Fuel filter replacement

Important
Before proceeding with operation, read
Warning
In case of low use replace il 12 months.
1. Procure a suitable container to collect the fuel.
2. Rotate the filter A to take it to the unlocked position and
remove it.
3. Lubricate the gasket C.
Assemble the filter A on the support B and rotate it until
reaches the lock position.
Important
Do not fill the new cartridge A with fuel.
4. Turn the key on the control panel to the ON position.
The electric pump D sends fuel to the filter and then the
injection pump E.
5. Loosen the air bleeding screw F on fuel filter bracket B.
The air inside the circuit and the filter will begin to
escape from the screw G.
6. Tighten the bleeding screw F (tightening torque of 1.5
Nm) when the fuel begins to flow.
Warning
Check that the fuel supply pump filter is present, and
replace if necessary.
1. Release the clamp D.
2. Demount the hose E.
3. Unscrew the filter G from the pump Q.
EN
78
INFORMATION FOR REPLACING THE
FUNCTIONAL UNITS
Par. 3.3.2.
Fig 6.74
Fig 6.75

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents