2
2.10.3 Oil filter and Oil Cooler
Fig 2.1 6
NOTE : unscrewing the cartridge holder cover makes the oil in support 7 flow towards the oil sump by
means of the drain duct 4.
Tab 2.22
POS.
DESCRIPTION
1
Oil arriving from the pump
2
Oil cooling
3
Oil filtering
4
Oil drain duct (oil sump return)
5
Oil returning into the circuit
6
Outgoing fitting from filter
7
Oil filter support
8
Cartridge holder cover
9
Oil filter cartridge
10
Oil Cooler
11
Crankcase
12
Oil directly from the cartridge
13
Coolant
14
Oil drain duct closure gasket
15
Oil filtering chamber closure gasket
16
Cartridge holder cover gasket
Tab 2.23 Cartridge characteristics.
DESCRIPTION
Filtering surface
Degree of filtration
Max operating pressure
Max flow rate
EN
28
TECHNICAL INFORMATION
VALORE
2
2.300 cm
2 µm
4.0 Bar
190 litres/hour
Fig 2.17