Toshiba MMK-UP0051DHPL-E(TR) Service Manual page 40

Table of Contents

Advertisement

DN
Item
33
T
e
m
p
e
a r
u t
e r
u
n
t i
E
x
e t
n r
a
s l
a t
c i t
p
e r
High-ceiling adjustment
5d
(Air flow selection)
Timer setting
60
(wired remote controller)
77
Dual set point
Alarm output setup of the
79
header unit
b3
Soft cooling
Whether the power
d0
saving mode can be set
by the remote controller
Destination
E0
W
i
e r
e l
s s
e r
m
o
e t
E6
controller A-B selection
Presence of Application
F6
control kit
(TCB-PCUC2E)
FC
Communication protocol *2
Priority operation mode
Fd
(FS unit)
FS unit address
FE
Notice code
180
number 01
Notice code
181
number 02
Notice code
182
number 03
Notice code
183
number 04
Notice code
184
number 05
Notice code
185
number 06
Notice code
186
number 07
Notice code
187
number 08
Notice code
188
number 09
Notice code
189
number 10
103
Remote controller
1A5
Airpure operation control
Central device control state 0000: No central device control (Remote controller use is possible)
1FB
Indoor Unit
1FC
terminating resistance
*1 Display order of "00Un"and "0099" varies depending on remote controller models or communication types.
s
e
e l
t c
0
0
0
0
° :
C
s s
u
e r
R
f e
r e
o t
n
e
t x
p
a
g
0000: Available
(can be performed)
0000: Unavailable
0000: Not including the state
of following unit
0000: Unavailable
0000: Invalid
0000: Domestic
0004: Global
0
0
0
: 0
A
0000: None
0000 TCC-LINK
0000: Heating
0001: No.1 unit
0001: No.1 unit
00Un: Unfixed (When using U series remote controller)
0099: Unfixed (Other than U series remote controller)
0000: None
0001 ~ 0255 : Notice code
0129 : Notice code (201)
0130 : Notice code (202)
(0001 ~ 0255 : TU2C-LINK only)
0000 Use
0000 Standard
0002 Airpure operation 75%
0001: Central device control (Remote controller use is impossible)
0000: OFF
Description
0
0
0
: 1
F °
. e
0001: Unavailable
(cannot be performed)
0002: Available
0001: Including the state of
following unit
0001: Available
0001: Valid
0003: China
0
0
0
: 1
B
0001: Exist
0003:TU2C-LINK
0001: Cooling
to
0064: No.64 unit
... TCC-LINK
to
0128: No.128 unit ... TU2C-LINK
0001 Do not use
0001 Airpure operation 100%
0003 Airpure operation 50%
0001: ON
- 40 -
At shipment
0
0
0
0
° :
C
Depending on model
type
0000: Available
0000: Unavailable
0000: Not including the
state of following
unit
0001: Available
0001: Valid
0004: Global
0
0
0
: 0
A
0000: None
0000: TCC-LINK
0000: Heating
00Un/0099: Unfixed *1
0000: None
0000: None
0000: None
0000: None
0000: None
0000: None
0000: None
0000: None
0000: None
0000: None
0000 Use
0000 Standard
0000: No central
device control
0000: OFF