Toshiba MMK-UP0051DHPL-E Owner's Manual
Hide thumbs Also See for MMK-UP0051DHPL-E:

Advertisement

Quick Links

R32 or R410A
AIR CONDITIONER (MULTI TYPE)
Owner's Manual
For wireless remote controller
Indoor Unit
For commercial use
Model name:
High-Wall Type
MMK-UP0051DHPL-E
MMK-UP0071DHPL-E
MMK-UP0091DHPL-E
MMK-UP0121DHPL-E
MMK-UP0151DHPL-E
MMK-UP0181DHPL-E
When the DHPL model (MMK-UP*DHPL-E) is installed,
PMV kit is necessary.
Owner's Manual
1
English
1133850201

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba MMK-UP0051DHPL-E

  • Page 1 R32 or R410A AIR CONDITIONER (MULTI TYPE) Owner’s Manual For wireless remote controller Indoor Unit For commercial use Model name: High-Wall Type MMK-UP0051DHPL-E MMK-UP0071DHPL-E MMK-UP0091DHPL-E MMK-UP0121DHPL-E MMK-UP0151DHPL-E MMK-UP0181DHPL-E When the DHPL model (MMK-UP*DHPL-E) is installed, PMV kit is necessary. Owner’s Manual...
  • Page 2 Owner’s Manual Original instruction Thank you very much for purchasing TOSHIBA Air Conditioner. Please read this owner’s manual carefully before using your Air Conditioner. • Be sure to obtain the “Owner’s manual” and “Installation manual” from constructor (or dealer). • Request to constructor or dealer.
  • Page 3: Table Of Contents

    Owner’s Manual Contents PRECAUTIONS FOR SAFETY ..............6 ACCESSORIES ................... 12 PARTS NAME ....................12 PARTS NAME OF REMOTE CONTROLLER ..........14 LIMITED OPERATION BY GROUP CONTROL .......... 20 HINTS FOR ECONOMICAL OPERATION ..........21 TEMPORARY OPERATION ................ 22 MAINTENANCE ................... 23 TROUBLES AND CAUSES .................
  • Page 4 Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work.
  • Page 5 Owner’s Manual These safety cautions describe important matters concerning safety to prevent injury to users or other people and damages to property. Please read through this manual after understanding the contents below (meanings of indications), and be sure to follow the description. Indication Meaning of Indication Text set off in this manner indicates that failure to adhere to the directions in the...
  • Page 6 Owner’s Manual ■ Warning indications on the air conditioner unit Warning indication Description WARNING WARNING ELECTRICAL SHOCK HAZARD ELECTRICAL SHOCK HAZARD Disconnect all remote Disconnect all remote electric power supplies before electric power supplies servicing. before servicing. WARNING WARNING Moving parts. Moving parts.
  • Page 7: Precautions For Safety

    Owner’s Manual PRECAUTIONS FOR SAFETY DANGER • Do not attempt to install this unit by yourself. This unit requires qualified installer. • Do not attempt to repair the unit by yourself. This unit has no components which you can repair. •...
  • Page 8 Owner’s Manual • When the air conditioner must be transported by hand, carry it by two or more people. Installation • Only a qualified installer (*1) or qualified service person (*1) is allowed to carry out the electrical work of the air conditioner. Under no circumstances must this work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and/or electrical leaks.
  • Page 9 Owner’s Manual • Do not touch the aluminum fin of the outdoor unit. You may injure yourself if you do so. If the fin must be touched, do not touch it yourself but contact a qualified installer (*1) or qualified service person (*1). •...
  • Page 10 Owner’s Manual • If there is a danger of the outdoor unit’s toppling over, do not approach the outdoor unit but set the circuit breaker to the OFF position, and contact a qualified installer (*1) or a qualified service person (*1) to have the improvements or refitting done.
  • Page 11 Owner’s Manual • Do not leave flammable sprays or other flammable materials near the air conditioner, and do not spray flammable aerosol directly to the air conditioner. They may catch fire. • Stop running the air conditioner and turn off the breaker before cleaning. Otherwise, injury may result as the fan is rotating at high speed inside the unit.
  • Page 12 Owner’s Manual ■ Information on the transportation, handling and storage of the carton ◆ Examples of indication on the carton Symbol Description Symbol Description Keep dry Do not drop Fragile Do not lay down Stacking height (8 cartons can be stacked Do not walk on this carton in this case) This side up...
  • Page 13: Accessories

    Owner’s Manual ACCESSORIES Remote controller Remote controller holder Batteries (two) PARTS NAME ■ Indoor unit 8, 9 Room temperature sensor Horizontal airflow louver Front panel Vertical airflow louver Air inlet grille Display panel Air filter Infrared signal receiver Air outlet Remote controller (wireless) Remote controller (wired, sold separately) - 12 -...
  • Page 14 Owner’s Manual ■ Names and functions of CAUTION indicators and controls on • Disagreement in operation mode indoor unit If you select AUTOMATIC OPERATION in a model with no auto-changeover (cooling/ heating) Display panel control setting or if you select HEAT in a Cool Only model, an alarm sound (pi, pi) from the air conditioner due to disagreement in operation mode.
  • Page 15: Parts Name Of Remote Controller

    Owner’s Manual PARTS NAME OF REMOTE CONTROLLER Remote control Air fl ow direction 1 Infrared signal emitter Press 2 Start/Stop button Move the louver in 3 Mode select button the desired vertical 4 Temperature button direction. 5 Fan speed button 6 Menu select button Press : Move...
  • Page 16 Owner’s Manual Menu setup CAUTION For select more setting of Air conditioner such as Disagreement in operation mode Louver select, Hi Power, OFF Timer and other use If you select AUTOMATIC OPERATION in a model MENU button with no auto-changeover (cooling/heating) control MENU setting or if you select HEAT in a Cool Only model, lamp lights up and...
  • Page 17 Owner’s Manual 2. Enter Louver set by press MENU button again triangle mark will stop blink and setting feature 8.2 Hi POWER operation will be blink instead. To automatically control room temperature and MENU airflow for faster cooling or heating operation Blink (except in DRY and FAN ONLY mode) 1.
  • Page 18 Owner’s Manual 8.3 ECO operation 8.4 TIMER OFF operation To set the timer OFF when the air conditioner is To automatically control room temperature to save operating. energy (except in DRY and FAN ONLY mode) 1. Press MENU button for enter menu setting and 1.
  • Page 19 Owner’s Manual Cancel TIMER OFF 8.5 PURE (IONIZER) operation 6. During TIMER OFF already set (no.5) press Capture efficiency of floating impurities in the air MENU button and press TEMP. button to select is accelerated by Ionizer contaminates such as TIMER OFF.
  • Page 20 Owner’s Manual Auto restart function setting Remote control A-B selection This product is designed so that, after a power To separate using of remote control for each indoor failure, it can restart automatically in the same unit in case of 2 air conditioners are installed operating mode as before the power failure.
  • Page 21: Limited Operation By Group Control

    Owner’s Manual LIMITED OPERATION BY GROUP CONTROL NOTE Group control: Operate air conditioners in more than one system in same time. Header indoor unit: The representative unit during group control. Receive commands from wired remote controller and transmit the commands to follower units. (Header indoor unit is indoor unit that receives START/STOP signal from the wireless remote control.) Follower indoor unit: Indoor units other than the Header unit are called follower unit.
  • Page 22: Hints For Economical Operation

    Owner’s Manual HINTS FOR ECONOMICAL OPERATION ■ Maintain room temperature at comfortable level Clean air filters The clogged air filters impairs the performance of the air conditioner. Gee, chilly Clean them once two weeks. Control Never open doors and windows more often than necessary Clean, please To keep cool or warm air in the room, never open...
  • Page 23: Temporary Operation

    Owner’s Manual TEMPORARY OPERATION ■ TEMPORARY operation This function is used to operate the unit temporarily in case you misplace the wireless remote controller or its batteries are exhausted. • Push the [RESET] button once (less than 3 seconds) to start the air conditioner. •...
  • Page 24: Maintenance

    Owner’s Manual MAINTENANCE WARNING Before you clean the air conditioner, be sure to turn off the circuit breaker or main power switch. ■ Cleaning of indoor unit and remote controller CAUTION • Use a dry cloth to wipe the indoor unit and remote controller. •...
  • Page 25 Owner’s Manual ■ Cleaning the air fi lter 2. Take hold of the left and right handles of the air filter and lift it up slightly, then pull it downward Clean the air filters every 2 weeks. If the air filters to take it out from the filter holder.
  • Page 26: Troubles And Causes

    Owner’s Manual TROUBLES AND CAUSES For contents of the outdoor unit, combinations, etc., refer to the owner’s manual supplied with the outdoor unit. CAUTION If any of the following conditions occur, stop the air conditioner immediately, set to off the main power switch and contact the dealer: •...
  • Page 27 Owner’s Manual ▼ These are not failures. The back of indoor unit is dewed. • Dewdrops on the back of the indoor unit are automatically collected and drained out. Indoor unit or outdoor unit makes a strange noise. • When temperature sharply changes, the indoor or outdoor unit occasionally makes a strange noise because of expansion/contraction of parts or change of refrigerant flow.
  • Page 28: Specifications

    Product information of ecodesign requirements. (Regulation (EU) 2016/2281) http://ecodesign.toshiba-airconditioning.eu/en Declaration of Conformity Manufacturer: Toshiba Carrier (Thailand) Co., Ltd. 144 / 9 Moo 5, Bangkadi Industrial Park, Tivanon Road, Tambol Bangkadi, Amphur Muang, Pathumthani 12000, Thailand TCF holder: TOSHIBA CARRIER EUROPE S.A.S...
  • Page 29 Owner’s Manual Declaration of Conformity Manufacturer: Toshiba Carrier (Thailand) Co.,Ltd. 144 / 9 Moo 5, Bangkadi Industrial Park, Tivanon Road, Tambol Bangkadi, Amphur Muang, Pathumthani 12000, Thailand TCF holder: TOSHIBA CARRIER UK LTD. Porsham Close Belliver Industrial Estate Roborough Plymouth Devon...
  • Page 30 144 / 9 Moo 5, Bangkadi Industrial Park, Tivanon Road, Tambol Bangkadi, Amphur Muang, Pathumthani 12000, Thailand 144 / 9 Moo 5, Bangkadi Industrial Park, Tivanon Road, Tambol Bangkadi, Amphur Muang, Pathumthani 12000, Thailand 1133850201...

Table of Contents