  • Page 1 AIR CONDITIONER (MULTI TYPE) Owner's Manual R32 or R410A For wireless remote controller Indoor Unit Model name: For commercial use High-Wall Type MMK-UP0271HP-E MMK-UP0301HP-E MMK-UP0361HP-E Scan QR CODE to access installation and owner’s manual on website. https://www.toshiba-carrier.co.th/manuals/default.aspx Manual are available in AR/BG/CZ/DA/DE/EL/EN/ES/ET/FI/FR/ HR/HU/IT/LT/LV/NL/NO/PL/PT/RO/RU/SK/SL/SV/TR.
  • Page 2 Thank you very much for purchasing TOSHIBA Air Conditioner. Please read this owner’s manual carefully before using your Air Conditioner. Be sure to obtain the “Owner’s manual” and “Installation manual” from constructor (or dealer). Request to constructor or dealer Please clearly explain the contents of the Owner’s manual and hand over it.
  • Page 3: Parts Name

    ACCESSORIES PARTS NAME Indoor unit 5 6 7 8 9,10 - 2 - 2-EN...
  • Page 4: Names And Functions Of Indicators And Controls On Indoor Unit

    Names and functions of CAUTION indicators and controls on • Disagreement in operation mode indoor unit If you select AUTOMATIC OPERATION in a model with no auto-changeover (cooling/heating) control setting or if you select HEAT in a Cool Only model, an alarm sound (pi, pi) from the air conditioner due to disagreement in operation mode.
  • Page 5: Wireless Remote Controller And Its Functions

    PARTS NAME OF REMOTE CONTROLLER Wireless remote controller and its You can also manually select the desired fan speed functions from among ve settings. (LOW , LOW , MED , HIGH (A receiving beep is heard.) Press this button to swing the louver. (A receiving beep is heard.) Press the SWING button to stop the louver swinging.
  • Page 6: Names And Functions Of Indications On Wireless Remote Controller

    Names and functions of indications on wireless remote Indicated during the OFF timer operation that controller automatically adjusts the room temperature and the fan speed. Each time you press the COMFORT SLEEP button, the display changes in the sequence of 1h, 3h, 5h, and 9h. All indications, except for clock time indication, are indicated by pressing the START/STOP button.
  • Page 7: Adjusting Clock

    Clock adjusting ADJUSTING CLOCK Before you start operating the air conditioner, set the clock of the remote controller using the procedures given in this section. The clock panel on the remote controller will indicate the time regardless of whether the air conditioner is in use or not.
  • Page 8: Handling The Remote Controller

    HANDLING THE REMOTE CONTROLLER Remote controller holder CAUTION • The air conditioner will not operate if curtains, doors or other materials block the signals from • Before you actually install the remote controller the remote controller to the indoor unit. holder on a wall or pillar, check whether the •...
  • Page 9: Cooling/Heating/Fan Only Operation

    HOW TO USE REMOTE CONTROLLER Cooling/heating/fan only operation Dry operation SWING SWING Press this button to start the air conditioner. Press this button to start the air conditioner. Select Dry Select Cool , Heat , or Fan only Set the desired temperature. Set the desired temperature.
  • Page 10: Automatic Operation (Auto Changeover)

    Automatic operation Timer operation (auto changeover) Use the wired remote controller for timer setting if it is also in use. This function is available only for use in combination with a heat recovery model outdoor unit. If this function is used with another model of outdoor unit, “A”...
  • Page 11 Once you select the timer operation mode, the settings are saved in the remote controller. Thereafter, the air conditioner will start operating You can use this setting to start the air conditioner under the same conditions when you simply press when you wake up and stop it when you leave the the ON/OFF button of the remote controller.
  • Page 12: High Power Operation

    High power operation Quiet operation • The QUIET mode provides quiet operating status by automatically setting the fan speed to the • The Hi POWER (high power operation) mode lowest speed. automatically controls room temperature, air ow and operation mode so that the room is quickly cooled in summer and warmed in winter.
  • Page 13: Preset Operation

    Preset Operation CAUTION Set your preferred operation mode for future use. The COMFORT SLEEP mode is not enabled in the The setting is memorized by the unit for future DRY or FAN ONLY operation. operation (except air ow direction). NOTE •...
  • Page 14 Adjusting air ow direction Perform this function when the air conditioner is in • Adjust the air ow direction properly. Otherwise, operation. it might cause discomfort and make the room temperature uneven. • Adjust the vertical air ow using the remote controller.
  • Page 15: Wireless Remote Controller A-B Selection

    Wireless remote controller CAUTION A-B selection • The FIX and SWING buttons will be disabled Using 2 wireless remote controllers for the when the air conditioner is not in operation respective air conditioners, when the 2 air (including when the ON timer is set). conditioners are closely installed.
  • Page 16: Limited Operation By Group Control

    LIMITED OPERATION BY GROUP CONTROL NOTE Group control: Operate air conditioners in more than one system in same time. Header indoor unit: The representative unit during group control. Receive commands from wired remote controller and transmit the commands to follower units. (Header indoor unit is indoor unit that receives START/STOP signal from the wireless remote control.) Follower indoor unit: Indoor units other than the Header unit are called follower unit.
  • Page 17: Hints For Economical Operation

    HINTS FOR ECONOMICAL OPERATION Maintain room temperature at comfortable level The clogged air lters impairs the performance of the air conditioner. Gee, chilly Clean them once two weeks. Control Clean, please To keep cool or warm air in the room, never open doors and windows more often than necessary.
  • Page 18: Temporary Operation

    TEMPORARY OPERATION TEMPORARY operation This function is used to operate the unit temporarily in case you misplace the wireless remote controller or its batteries are exhausted. • Push the [RESET] button once (less than 3 seconds) to start the air conditioner. •...
  • Page 19: Maintenance

    MAINTENANCE WARNING Before cleaning the air conditioner, to turn off the circuit breaker or main power switch. After the cooling or dry auto (cooling) operation has nished, the self clean operation is performed and the fan starts running. Before cleaning the unit, stop the self clean operation forcibly and turn off the circuit breaker to avoid electric shock.
  • Page 20: Cleaning The Air Lter

    Cleaning the air lter 4. Insert the upper portion of air lter con rming to t its right and left edges on the indoor unit until Clean the air lters every 2 weeks. If the air lters it is rmly set. are covered with dust, the performance of the air conditioner will deteriorate.
  • Page 21 When not used for a long time 3. Wipe out water from the air inlet grille and dry it. 1. Perform the fan operation for a couple of hours 4. Fit the left and right arms of the air inlet grille to to dry inside.
  • Page 22: Troubles And Causes

    TROUBLES AND CAUSES For contents of the outdoor unit, combinations, etc., refer to the owner’s manual supplied with the outdoor unit. CAUTION If any of the following conditions occur, stop the air conditioner immediately, set to off the main power switch and contact the dealer: •...
  • Page 23 These are not failures. • Dewdrops on the back of the indoor unit are automatically collected and drained out. • When temperature sharply changes, the indoor or outdoor unit occasionally makes a strange noise because of expansion/contraction of parts or change of refrigerant ow. •...
  • Page 24 Product information of ecodesign requirements. (Regulation (EU) 2016/2281) http://ecodesign.toshiba-airconditioning.eu/en Declaration of Conformity Manufacturer: Toshiba Carrier (Thailand) Co., Ltd. 144 / 9 Moo 5, Bangkadi Industrial Park, Tivanon Road, Tambol Bangkadi, Amphur Muang, Pathumthani 12000, Thailand TCF holder: TOSHIBA CARRIER EUROPE S.A.S...
  • Page 25 Declaration of Conformity Manufacturer: Toshiba Carrier (Thailand) Co., Ltd. 144 / 9 Moo 5, Bangkadi Industrial Park, Tivanon Road, Tambol Bangkadi, Amphur Muang, Pathumthani 12000, Thailand TCF holder: TOSHIBA CARRIER UK LTD. Porsham Close Belliver Industrial Estate Roborough Plymouth Devon...
  • Page 26 144 / 9 Moo 5, Bangkadi Industrial Park, Tivanon Road, Tambol Bangkadi, Amphur Muang, Pathumthani 12000, Thailand 1130550211A...