Adjustment Procedure - Kenwood MIDl M-85 Instruction Manual

Midi compact audio system
Table of Contents

Advertisement

DELAY TIME keys
@ Adjustment Procedure
1
Set for DOPro Logic or O03 Stereo.
PRO LOGIC
13 STEREO
O00
LOPRO-LOGIC
13 STEREO
2 Select the CENTER MODE.
CENTER
MODE
Changes as shown below each time the key is pressed.
When at DOPro Logic
NORMAL —»
WIDE —-» PHANTOM
When atQ0 3 Stereo
NORMAL +>
WIDE
Press the TEST key.
alas
Left
Center
Right
A buzzing sound comes from
the speaker. Changes as
shown each time the key
is pressed.
every two
every one
seconds——» second —~
OFF
2
Tpche
oO
@ Press at the listening position.
@ When at Pro Logic, sound is produced in the following se-
quence: LEFT > CENTER > RIGHT > REAR.
@ When at 3 Stereo, sound is produced in the sequence: LEFT
-
CENTER
RIGHT (REAR not available with 3 stereo
mode.)
@ When
at PHANTOM,
sound
is produced
in the sequence:
LEFT — RIGHT > REAR each time the key is pressed.
42 85-959 (En)
OO PRO LOGIC/
DO 3 STEREO key
CENTER MODE key
REAR VOL. keys
CENTER VOL. keys
4 Adjust so that the same sound volume
comes from each speaker.
@® Align with sound volume of center speaker.
@ Adjust within a range of -78 to 0 dB. Adjustment to DO3 Ster-
eo mode is not possible.
CENTER VOL.
+
CENTER VOL.
"S
® Align with sound volume of rear speaker.
@ Adjust within a range of -78 to 0 dB.
a
REAR VOL
a
CUT)
REAR VOL
.
.
@ Adjust the rear volume so that the sound volumes from the
rear speakers are the same.
@ In the case of 3 Stereo, since there is no rear speaker, adjust
so that the sound volumes from the three front speakers are
all the same.
@ These adjustments are not possible when the center and rear
speaker selector switches are set to eff.
5 Set the test tone to OFF.| Remote control only
Press the TEST key.
=
6 Set the delay time.
DELAY
TIME
Co)
@ Delay time is not set at 3 Stereo.
@ Adjust within a range of 15 to 30ms based on formula given
on page 41.
@ Adjustment can be made in increments of 1 ms each time the
DELAY TIME keys is pressed.
@ When the mode is switched, the initial setting value is re-
stored.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Midl m-959

Table of Contents