17 Troubleshooting

16.2.3.9.1 Explanation of parameters: 5 Communication
SETUP
Service
1
16.2.3.9.1.1 13.5.1. Setting the fieldbus parameters
Fieldbus:
Only available in fieldbus version
For details see separate operating instructions.
16.2.3.9.1.2 13.5.2. Setting the communication parameters
▶ For details on how to use the GEMÜ e.sy-com interface and operating the browser see separate operating instructions.
WebServer:
Submenu for setting the communication parameters
RS 232:
Defines the type of RS 232 connection
Auto
with connection to a PC/laptop or industrial modem
Serial
with connection to a PC/laptop
Bdrate RS:
Defines the transmission rate of the serial connection.
Bdrate RS
38400 baud
57600 baud
115,200 baud (default setting)
17 Troubleshooting
No.
Error message
000
NO ERROR
There are no errors
010
Iw < 4 mA
The set value signal is
lower than 4 mA
Error
011
Iw > 20 mA
The set value signal is
higher than 20 mA
Error
012
Ix < 4 mA
The actual value signal is
lower than 4 mA
Error
013
Ix > 20 mA
The actual value signal is
higher than 20 mA
Error
GEMÜ 1436 cPos
SetBasics
SetFunction
2
3
Description
Condition for the occurrence
-
The positioner is in auto-
matic mode
The positioner is in auto-
matic mode
The process controller is
active
The process controller is
active
SetCalibration
4
NOTICE
of the error
-
A cable break at the set value in-
put
The set value signal is higher
than 20 mA
A cable break at the actual value
input
The actual value signal is higher
than 20 mA
64 / 76
Communication
Return
5
6
Error cause
www.gemu-group.com