11 Assembly
4. Mount the black housing of the rotary travel sensor 4 in
parallel to the mounting bracket 6 in a longitudinal direc-
tion.
5. Mount the external rotary travel sensor 7 with the adapter
4 on the mounting bracket 6.
6. Note the direction of the scale 8.
ð View from below of the travel sensor 7 with mounting
bracket 6.
GEMÜ 1436 cPos

11.6 Direct mounting on linear actuators

4
6
1. Mount (see "Linear travel sensor mounting kit assembly
for remote mounting", page 18)the travel sensor mounting
kit.
2. Move the actuator 3 to the open position.
3. Guide the product 1 as far as it will go into the actuator
7
opening or the adapter, and screw it in in a clockwise dir-
ection against the initial spring tension, and tighten it us-
ing a suitable WAF27 open-ended spanner.
4. Connect the product's pneumatic supply and connect the
4
product to the process valve.
6
Damage to internal stop
▶ Do not turn the internal stop when assembling the
product.
If correctly mounted to the corresponding valve, the product
can be turned 320°.
7
6
8
20 / 76