Adjusting The Basic Position Of The Clutch Lever; Checking/Correcting The Fluid Level Of The Hydraulic Clutch - KTM F8475S0 2019 Owner's Manual

Table of Contents

Advertisement

11 SERVICE WORK ON THE CHASSIS
11.42
11.43
80

Adjusting the basic position of the clutch lever

F00157-10

Checking/correcting the fluid level of the hydraulic clutch

Warning
Skin irritation Brake fluid causes skin irritation.
Keep brake fluid out of the reach of children.
Wear suitable protective clothing and safety glasses.
Do not allow brake fluid to come into contact with the skin, the eyes or clothing.
Consult a doctor immediately if brake fluid has been swallowed.
Rinse the affected area with plenty of water in the event of contact with the skin.
Rinse eyes thoroughly with water immediately and consult a doctor if brake fluid comes into contact
with the eyes.
If brake fluid spills on to your clothing, change the clothing.
Info
The fluid level rises with increasing wear of the clutch facing discs.
Never use DOT 5 brake fluid. It is silicone-based and purple in color. Oil seals and clutch lines are not
designed for DOT 5 brake fluid.
Avoid contact between brake fluid and painted parts. Brake fluid attacks paint.
Only use clean brake fluid from a sealed container.
F00158-10
Adjust the basic position of the clutch lever to your hand size
by turning adjusting screw
Info
Turn the adjusting screw counterclockwise to decrease
the distance between the clutch lever and the handle-
bar.
Turn the adjusting screw clockwise to increase the
distance between the clutch lever and the handlebar.
The range of adjustment is limited.
Only turn the adjusting screw by hand, and do not use
force.
Do not make any adjustments while riding.
Move the clutch fluid reservoir mounted on the handlebar to a
horizontal position.
1
Remove screws
.
2
Remove cover
with membrane
Check the fluid level.
Fluid level below container
rim
»
If the fluid level does not meet specifications:
Correct the fluid level of the hydraulic clutch.
Brake fluid DOT 4 / DOT 5.1 (
Position the cover with the membrane. Mount and tighten the
screws.
1
.
3
.
4 mm (0.16 in)
p. 138)