Grounding

Provision is made for both protective ground (earthing) and functional ground (earthing).
In addition, where the installation of telephone and/or other standard (tip/ring) devices in
another building is required, In-Range-Out-Of-Building (IROB) protectors must be fitted
(see page 36).

Protective Ground

A protective ground must be permanently fitted to IP400 Analog Trunk 16 modules (see
page 27). Connection of this protective ground requires the use of suitable tools and must
be connected at both ends before connection is made to the telecommunications
network.
To connect the protective ground:
1. Attached one end of a #14 AWG (minimum) solid insulated cable (sleeve must be
green/yellow) to the Protective Ground Point as shown below.
Ensure that the Ground Post securing screw is fully tightened.
(M4 pan head screw with shakeproof washer)
Analog Trunk 16 Module
(Rear view)
2. Connect, using a fastening that satisfies local regulations, the other end of the wire to
the approved protective ground.

Functional Ground

To ensure proper operation of the IP Office equipment, functional grounding is required:
Caution:
On some models of the units/expansion modules, there may not be a specific M4
functional ground point. In which case use either the Trunk module kit fixing screw or the
top cover centre fixing screw as shown below:
To connect the functional ground:
1. Attached one end of a #14 AWG (minimum) solid insulated cable (sleeve must not be
green/yellow) to the grounding screw and fully tightened.
2. Connect, using a fastening that satisfies local regulations, the other end of the wire to
the approved ground, such as building steel or an earthed metal cold water pipe.
IP Office Installation Manual
40DHB0002UKCL – Issue 9 (28 October 2003)
Protective Ground Point
This functional ground is not a protective ground – see above for protective
grounding.
Use this M3 grounding screw, with int.
teeth washer, when M4 is not fitted
IP403
or
IP406
ANALOG TRUNK
1
or
IP412
Functional Ground Point
M4 pan head screw with shakeproof washer
2
3
4
Slot B
Grounding - Page 35
EXPANSION
PF1
PF2
Use centre cover fixing screw,
when M4 is not fitted
Expansion
Modules
Preparing for Installation - Page 35