Check the appliance is electrically safe and gas sound when you have nished.

Fitting the Wall Connector

The wall connector needs to be tted prior to the installation
of your cooker. The wall connector must be positioned in the
shaded grey area shown in Fig.8-1, in order to secure a safe
location for the gas supply. The wall connector is suitable for
a 15 mm (outside diameter) copper pipe soldered connection
(Fig.8-2).
Warning! Positioning the wall connector outside
n
n
of the shaded area could lead to re and property
damage.

Positioning the Cooker

Fig.8-3 and Fig.8-4 show the minimum recommended
distance from the cooker to nearby surfaces.
The cooker should not be placed on a base.
Above hotplate surround should be level with, or above, any
adjacent work surface.
A gap of 33 mm should be left between each side of the
cooker ABOVE the hotplate level and any adjacent vertical
surface.
For non-combustible surfaces (such as unpainted metal or
ceramic tiles) this gap is not required.
A minimum space of 800 mm is required between the top of
the hotplate and a horizontal combustible surface.
Any cookerhood should be installed in accordance with
the hood manufacturer's instructions.
Surfaces of furniture and walls at the sides and rear of the
appliance should be heat, splash and steam resistant. Certain
types of vinyl or laminate kitchen furniture are particularly
prone to heat damage and discolouration.
We cannot accept responsibility for damage caused by
normal use of the cooker to any material that de-laminates
or discolours at temperatures less than 65 °C above room
temperature.
We recommend a gap of 1200 mm between units to allow
for moving the cooker. Do not box the cooker in – it must
be possible to move the cooker in and out for cleaning and
servicing.
If the cooker is near a corner of the kitchen, a clearance of
90 mm is required to allow the oven doors to open (Fig.8-5).
The actual opening of the doors is slightly less but this allows
for some protection of your hand as you open the door.
INSTALLATION
Wall connector location
Cooker
location
Floor
Wall connector
5 mm
22
250 mm
350 mm
150 mm
Wall connector
Valve
800 mm
min
33 mm
33 mm
min
min
0
0
0
0
0
0
0
0
0
1
1
2
2
100
100
220
220
180
140
3
3
180
140
ArtNo.110-0040 - 110 Mercury min spacings
1190 mm
Fig.8-1
Wall behind cooker
670 mm
Fig.8-2
Fig.8-3
920 mm
min
945 mm
max