Lumenradio Crmx™ Connection; Initial Setup; Configuration; Product Pairing - Chauvet onAir Panel 1 IP User Manual

Table of Contents

Advertisement

Setup
Lumenradio CRMX™ Connection
In optimal conditions, the onAir IP Panel 1 can operate up to 300 m (900 ft) away from the CRMX™
transmitter, The CRMX™ receiver in the onAir IP Panel 1 must be paired with the CRMX™ transmitter for
wireless operation.

Initial Setup

1. Turn the CRMX™ transmitter on.
2. Connect the CRMX™ transmitter to a DMX controller.
3. Place the onAir IP Panel 1 within 300 m from the CRMX™ transmitter.
4. Turn the onAir IP Panel 1 on.

Configuration

1. From the onAir IP Panel 1's control panel, go to DMX Address.
2. Select the start address, as with any other DMX compatible product.
3. Go to Wireless Setting > Receive On/Off.
4. Select On. (The Signal Strength Indicator will show a ? in front of the bars)
5. Press the reset button on the CRMX™ transmitter. (The Signal Strength Indicator on the
onAir IP Panel 1 will show a ϟ in front of the bars for 3 seconds while a connection is established.)

Product Pairing

If the onAir IP Panel 1 has already been paired with the CRMX™ transmitter, the Signal Strength Indicator
on top of the display will show the strength of the signal. In this case, the onAir IP Panel 1 is ready to work
in Wireless mode.
Pairing the onAir IP Panel 1 and a New CRMX™ Transmitter
1. From the onAir IP Panel 1 control panel, go to Wireless Setting > Receive Reset.
2. Select Yes.
3. From the CRMX™ transmitter, press <RESET>. The signal indicator on the transmitter will flash.
4. Once the transmitter has found the onAir IP Panel 1, the signal indicator on the CRMX™
transmitter will illuminate solid.
5. The display screen on the onAir IP Panel 1 will show the strength of the signal.
CRMX™ operation can be interrupted or inhibited by people or liquid masses, including
water or snow, between the transmitter and receiver. For best results, keep the area
between the transmitter and receiver clear of any liquid masses.

Accessory Slots

The onAir IP Panel 1 has 2 accessory slots that can be accessed by pressing the accessory slot tabs
inward and opening the hinged accessory slot cover.
Do not use when the diffuser is removed. The diffuser cannot be removed when the
fixture is powered on.
For fixed mounted luminaires, the risk group shall not exceed RG1 at the distance
obtaining 500 lx.
The back slot is for a diffuser or intensifier.
The front slot is for accessories such as a honeycomb or barn doors.