3. Setup

AC Power

The onAir IP Panel 1 has an auto-ranging power supply and it can work with an input voltage range of 100
to 240 VAC, 50/60 Hz.
To determine the product's power requirements (circuit breaker, power outlet, and wiring), use the current
value listed on the label affixed to the product's back panel, or refer to the product's specifications chart.
The listed current rating indicates the product's average current draw under normal conditions.
Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure
the product has an appropriate electrical ground to avoid the risk of electrocution or
fire.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel serves only as a 0 to 100% switch.

AC Plug

The onAir IP Panel 1 comes with a power input cord terminated with a Seetronic Powerkon IP65 connector
on one end and an Edison plug on the other end (U.S. market). If the cable has no plug or the plug needs
to be changed, use the table below to wire a plug.
Connection
AC Live
AC Neutral
AC Ground

Power Linking

It is possible to power link onAir IP Panel 1 products. See the table below for the current draw at each
voltage and frequency:
100 V, 60 Hz
Current Draw
1.862 A
Never exceed 12 A on a single circuit. Power-linking cables can be purchased separately.

DC Power

The onAir IP Panel 1 has a 3-pin IP65 XLR power input that can work with an input voltage of 28 VDC
which is SELV voltage supplied by short-circuit-proof power supply.
If AC power and DC power are input to the product at the same time, the product will
automatically give priority to AC power input.
6
Wire (U.S.)
Black
White
Green/Yellow
120 V, 60 Hz
208 V, 60 Hz
1.524 A
Wire (Europe)
Brown
Blue
Green/Yellow
230 V, 50 Hz
0.891 A
0.824 A
onAir IP Panel 1 User Manual Rev. 3
Setup
Screw Color
Yellow or Brass
Silver
Green
240 V, 50 Hz
0.795 A

Advertisement