N.B: The air intake and the flue outlet
must not terminate on opposite sides of
the building (EN 483).
Type C
13
Fig. 6.10
The minimum length of the pipes must be
less than 0.5 m, whilst the maximum sum
of routes A + B that can be realised with the
aid of extensions must not exceed 40 m for
Inovia 16S - Inovia 25S.
Bends of Ø 80 mm at 90° and at 45° are
available that reduce the maximum total
length of the pipes by:
For the bend of 45° loss
For the bend of 90° loss
Type C
53
Fig. 6.11
INSTALLATION
C
TYPE
63
If using pipes and terminals by other manu-
facturers (Type C
these are approved and in the case of flue
pipes, it is necessary to use materials com-
patible with condensation products.
During the pipes dimensioning phase, take
into consideration the static pressure resi-
due of the fan:
Useful static pres-
sure at nominal heat
input
Overheated flue
Maximum recircula-
tion of CO
suction duct
Roof flue exhaust kit (Fig. 6.12)
Coaxial pipe Ø 80/125 mm with a nominal
height of 0.96 m.
This kit exhausts directly to the roof.
Type C
0,9 m
1,65 m
90°
Fig. 6.12
45°
Extensions are available for reaching the
maximum height.
Its maximum height with extension is 10 m
for Inovia 16S - Inovia 25S. Bends of Ø 80
mm at 90° and at 45° are available that re-
duce the maximum total length of the pipes
), it is necessary that
63
16 kW
25 kW
16 kW
25 kW
16 kW
in the
2
25 kW
33
Ø 125
-
Pa
120
Pa
°C
-
°C
-
-
%
°C
-
90°
45°
- 47 -