List of Parameters
Pa-
Name
ram-
eter
No.
Used to the input characteristics of analog frequen-
n41
Frequency
reference
cy references.
gain
Gain: The frequency of maximum analog input (10
V or 20 mA) in ercentage based on the maximum
V or 20 mA) in percentage based on the maximum
frequency as 100%.
n42
Frequency
reference
Bias: The frequency of minimum analog input (0 V
bias
or 0 or 4 mA) in percentage based on the maxi-
mum frequency as 100%.
n43
Analog fre-
Used to set the digital filter with a first-order lag for
quency ref-
analog frequency references to be input.
erence time
n44
Analog
Used to set the output frequency or current as a
monitor out-
monitored item.
put
0: Output frequency (10-V output at max. frequen-
cy with n45 set to 1.00).
1: Output current (10-V output with Inverter rated
output current with n45 set to 1.00)
n45
Analog
Used to set the output characteristics of analog
monitor out-
monitor output.
put gain
n46
Carrier fre-
Used to set the carrier frequency.
quency
Note The default setting does not need any
selection
Note Refer to 6-1 Setting the Carrier Frequen-
n47
Momentary
Used to specify the processing that is performed
power inter-
when a momentary power interruption occurs.
ruption
0: Inverter stops operating
compensa-
1: Inverter continues operating if power interruption
tion
is 0.5 s or less.
2: Inverter restarts when power is restored.
n48
Fault retry
Used to set the number of times the Inverter is re-
set and restarted automatically in the case the In-
verter has an overvoltage fault, overcurrent fault, or
ground fault.
Used to set the frequency jump function.
n49
Jump fre-
quency 1
Output
frequency
n50
Jump fre-
quency 2
n51
Jump width
Note These values must satisfy the following
9-10
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Description
changes in normal operation.
cy for details.
n51
n50
n50
n49
n49
condition: n49  n50
Set-
Unit
ting
of set-
range
ting
0 to
1%
255
–99 to
1%
99
0.00 to
0.01 s
2.00
0, 1
1
0.00 to
0.01
2.00
1 to 4,
1
7 to 9
0 to 2
1
0 to 10 1
0.0 to
0.1 Hz
400
(see
note
1)
0.0 to
0.1 Hz
400
(see
note
Frequency
1)
reference
0.0 to
0.1 Hz
25.5
Chapter 9
Default
Changes
Ref-
setting
during
er-
opera-
ence
tion
page
100
Yes
5-9
0
Yes
5-9
0.10
No
5-10
0
No
5-23
1.00
Yes
5-23
Varies
No
6-2
with
the ca-
pacity.
0
No
6-15
0
No
6-15
0.0
No
6-16
0.0
No
6-16
0.0
No
6-16