Drive Indicator Codes - Dell E76S Installation And Service Manual

Hide thumbs Also See for E76S:
Table of Contents

Advertisement

Drive indicator codes

The LEDs on the drive carrier indicate the state of each drive. Each drive carrier has two LEDs: an activity LED (green) and a
status LED (bicolor, green/amber). The activity LED blinks whenever the drive is accessed.
Figure 185. Drive indicators on the drive and the mid drive tray backplane
1. Drive activity LED indicator
2. Drive status LED indicator
3. Drive capacity label
Figure 186. Drive indicators
1. Drive activity LED indicator
2. Drive status LED indicator
3. Drive capacity label
NOTE:
If the drive is in the Advanced Host Controller Interface (AHCI) mode, the status LED indicator does not power on.
NOTE:
Drive status indicator behavior is managed by Storage Spaces Direct. Not all drive status indicators may be used.
Table 56. Drive indicator codes
Drive status indicator code
Blinks green twice per second
Off
Blinks green, amber, and then powers off
Blinks amber four times per second
Blinks green slowly
Solid green
Condition
Indicates that the drive is being identified or preparing for removal.
Indicates that the drive is ready for removal.
NOTE:
The drive status indicator remains off until all drives are
initialized after the system is powered on. Drives are not ready
for removal during this time.
Indicates that there is an unexpected drive failure.
Indicates that the drive has failed.
Indicates that the drive is rebuilding.
Indicates that the drive is online.
System diagnostics and indicator codes