MIC Series 550
The table below identifies the number of alarm inputs and outputs available in MIC IR power
supply units. MIC IR PSUs do not have the option of a separate card for additional alarm
inputs or outputs.
MIC-IR-24PSU-UL,
MIC-IR-115PSU-UL,
MIC-IR-240PSU-UL
Table 12.4: Number of alarm inputs and outputs in MIC IR PSUs
12.5
Simultaneous IP and Analog Video/Control ("Hybrid"
Operation)
The figure below illustrates how to configure your system to achieve simultaneous video and
control over both IP and analog connections.
Figure 12.2: System configuration for simultaneous video/control
Number
1
2
3
4
5
Bosch Security Systems, Inc.
MIC PSU
Number of
Alarm Inputs
Description
Connection between MIC camera and BNC T-connector in BNC socket on PCB in
MIC IP PSU
Connection between BNC T-connector and encoder in MIC IP PSU
Connection between BNC T-connector and Bilinx-based control (head-end) system
Connection between Bilinx-based control (head-end) system and Local Area
Network (LAN) (or the "cloud")
Connection between the Local Area Network (LAN) and PC connected to video
monitor
Operation Manual
Number of
Alarm Outputs
4
0
Install the MIC (standard) PSU | en
2014.11 | 3.2 | F.01U.239.454
31