Vg4 Ip Autodome Video And Control - Bosch VG4-200 User Manual

Autodome modular camera system
Hide thumbs Also See for VG4-200:
Table of Contents

Advertisement

76
en | Troubleshooting Guide
Inside of
EnviroDome bubble
If status reports Heater No Power, then:
is foggy
If O.K., then:
Low Voltage flashing
on monitor display
If O.K., then:
If O.K., then:
If O.K., then:
10.2

VG4 IP AutoDome Video and Control

Problem
Solution
No Network
Connection
If O.K., then:
F.01U.133.267 | 6.0 (IP4) | 2009.06
Check the status of the Heater Module (ON-66-ENTER).
Turn off the power to the AutDome.
Check the FX103 fuse in the Power Supply Box for power (24 V) to the heater module.
Check all wiring and connector pins to the heater module.
If using a non-Bosch power supply, confirm that it meets the Bosch AutoDome power
ratings. See the AutoDome Datasheet for specifications.
Check the mains input line voltage.
Check that the maximum wire length from the power supply has not been exceeded.
See the AutoDome Modular Camera System Installation Manual.
Measure the AC voltage input to the camera while power is applied to the camera. The
voltage must be
21 VAC to stop the message.
Check all network connections
Ensure that the maximum distance between any two Ethernet connections is 100
m (328 ft) or less.
Refer to the AutoDome Modular Camera System Installation Manual for more infor-
mation.
If you are behind a firewall, ensure that the Video Transmission mode is set to UDP.
a.
Access the Settings Web page for the IP-enabled device.
b.
Expand the Service Settings link, then click Network.
c.
Select UDP from the Video Transmission drop-down list. Then click Set.