CLEANING & MAINTENANCE
4.1

COMMISSIONING

CLEANING
For all case cleaning activities cabinet should
be turned off. Electrical power should be safely
disconnected and refrigeration switched off. Once
all cleaning is completed, remember to turn it back
on safely.
Remove the PVC protective coating on stainless
steel, where applicable.
Remove any residue, silicon, or tape marks with a
cloth moistened with rubbing alcohol.
Remove all debris from in and around the case.
Wipe case with a clean, damp cloth, if necessary.
Doors:
At temperatures above 0°C hand wash with warm
»
water and using a mild detergent is recommended.
»
A glass cleaner can be used (Windex) using a towel.
Paper towels are not suggested.
Take care with cleaning, and avoid any materials
»
that may mark the door (including fingerprints).
Do not use tape, glue, stickers, attachments, magic
»
markers, or the like on the glass.
Do not use razor blades or any other mechanical
»
device to remove foreign residue or objects directly
from the glass.
Do not use abrasive cleaners or materials on the
»
glass like Ajax, Scotch Brite, or Steel Wool.
Do not use cleaners or materials on the glass that
»
hinder the anti-fog performance (if applicable),
by leaving a residue or damaging the surface.
Examples of these cleaners include: Armor All, Tilex,
Bleach, Windex No-Drip, Windex Wipes, Pledge, or
any product containing silicone oils or waxes.
Recommended
»
Lightning, Formula 409 Grease & Grim, Formula
409 Grease & Surface, Fantastic, Windex Vinegar,
Windex Original, Now, Mean Green, or Mr. Clean
(degreasing cleaners).
PAGE 28
cleaners
include:
Greased
START UP & CHECKS
Check supply power is ready and correct voltage.
(by Licensed Person).
Confirm correct operation of RCD (if fitted) (by
Licensed Person).
Ensure that the drain trap is installed the right way
up
(refer to figure 3Y for
the section installing the waste drain).
NOTE: Verify all electrical termination
during
requirement to check all electrical
connections for tightness, where
appropriate all electrical connections
must be re-tensioned prior to powering
up the cabinet.
TURN POWER ON
Check that all fans and lights (and light RCDs, if
installed) are working correctly.
Check the anti sweat circuit is working correctly.
Set expansion valves and EPRs as per Product
Engineering Data (Available from Hussmann).
Approximately 24 hours after start-up, check that
the case is at correct operating temperature (refer
the Product Engineering Data).
PSM15E3R SEMI-VERTICAL - HUSSMANN
drain trap orientation in
commissioning.
It
is
a