3.6

SEALING CASE JOINS

All cases must be sealed against water and air leakage
before joining.
To seal the joins:
1. Remove the shelving, racks, mirrors, etc., from the
end bays, where necessary. Cases must not be po-
sitioned in areas that may be subject to heat or air
currents such as ventilation ducts, open doors or
windows, direct sunlight, electric fans, ovens, etc.
2. Cases joints must be air tight to prevent formation
of ice or condensation. Foam tape has already
been fitted to the end of the case. Check to ensure
sealing integrity can be achieved. Remedy if foam
tape has been damaged before the final joining of
both cases together.
Foam Tape (Already Fitted)
PAGE 19
3.7
To join the cases
1. Draw up the required case tightly against the case
2. Ensure that the case is level, from front to back and
3. Insert the joining bolts (found in the blister pack),
FIGURE 3Q
CAUTION:
shelves when joining the cases.
Shelf light leads may need to be
disconnected prior to removal.

JOINING THE CASES

already in position.
side to side, with the existing case.
CAUTION:
Case joining bolts should
only be tightened when the cases have
been positioned as close together as
possible.
into the end holes and tighten.
PSM15E3R SEMI-VERTICAL - HUSSMANN
Take care if removing
FIGURE 3R