Condensing Unit; Cleaning The Condenser; Cleaning Exterior; Cleaning Interior - Hussmann DCCG-8 Installation And Service Instructions Manual

Dipping and display case
Hide thumbs Also See for DCCG-8:
Table of Contents

Advertisement

be taken not to puncture the interior
walls or remove paint from the walls
during this procedure.
Be sure to disconnect power from the
cabinet
prior
to
operation. After the cabinet is completely
defrosted,
wash
defrost water (Hussmann dipping cases
are provided with an outside drain
located on the operator's side of the case
base to assist you in this operation), wipe
the interior dry, and turn the power back
on.
Be sure to allow the cabinet to cool down
to
its
operating
reloading.
CONDENSING UNIT –
The condensing unit is mounted on a
slideout base, accessible by removing the
rear serving side access panel.
condenser is of the baretube design. The
condenser fan motor draws the air
through the rear access panel, across the
compressor and discharges back out the
rear access panel unless the case has been
Field converted to front air discharge as
previously discussed in the Location
section of this manual. For this reason, if
the case is installed in a counter, provisions
must be made for the release of the
discharge air.
CLEANING THE CONDENSER –
To clean condenser, a soft, nylon brush
should be used to loosen dirt and lint.
Then vacuum up the dirt or blow
condenser out with a high-pressure gas
such as nitrogen. Never use a wire brush
to clean condenser tubes.
starting
defrost
thoroughly,
remove
temperature
before
The
CLEANING EXTERIOR / INTERIOR –
When cleaning the exterior of the cabinet
use a soft cloth or sponge with water and
mild detergent. Rinse and wipe dry.
For cleaning the interior of the product
compartment, a built-in drain has been
provided with a standard hose fitting
located at the front of the cabinet in the
base area.
Disconnect the electrical
power and allow cabinet to warm to
above freezing temperature.
cloth or sponge with a mild detergent to
wash the interior.
restarting the cabinet. Allow the cabinet
to cool down to proper temperature
before reloading product.
SERIAL PLATE LOCATION –
One serial plate is located on the interior
left wall of the cabinet, and a second one
in the condensing unit compartment.
Both contain all pertinent information
such as model, serial number, amperage
rating, refrigerant type and charge, etc.
Specific charges are DCSG/DCCG-4 16
oz.,DCSG/DCCG-8 29 oz., DCSG/DCCG-
12 33 oz., and DCSG/DCCG-16 has 31
oz., all have R-404a.
have the same charge.
TEMPERATURE CONTROL
REPLACEMENT –
The Ranco temperature control is located
in the compressor compartment.
replace, first disconnect power supply and
remove two screws holding control dial
plate.
Pull capillary tube from control
well, noting length of tube removed. Push
new cap tube into well, being careful not
to kink it, and making certain it reaches
full depth of well.
7
Use a soft
Wipe dry before
The "D" models
To