P36D-NG10 System Data
For 0 to 4500 feet altitude
Burner Inlet Orifice Sizes: #37
Max. Input Rating: 30,000 Btu/h
Min. Input Rating: 15,500 Btu/h
Supply Pressure:
min.5.0" w.c.
Manifold Pressure
(High):
3.8"+/- 0.2"w.c.
Electrical: 120 V A.C. System.
Circulation Fan: variable speed 130 CFM.
Log Set: Ceramic fibre, 7 per set.
Vent System: Simpson Dura-Vent Direct
Vent System or Regency Direct Vent System (Flex)
P36D-LP10 System Data
For 0 to 4500 feet altitude
Burner Inlet Orifice Sizes: #52
Max. Input Rating: 30,000 Btu/h
Min. Input Rating: 15,000 Btu/h
Supply Pressure
min.12.0" w.c.
Manifold Pressure
(High)
11"+/- 0.2" w.c.
Electrical: 120 V A.C. System.
Circulation Fan: variable speed 130 CFM.
Log Set: Ceramic fibre, 7 per set.
Vent System: Simpson Dura-Vent Direct Vent
System or Regency Direct Vent System (Flex)
Regency
installation

HIGH ELEVATION

This unit is approved in Canada for altitude 0
to 4500 ft. (CSA 2.17) with the orifice supplied.
GAS LINE
INSTALLATION
The gas line is brought through the right of the
appliance. The gas valve is situated on the right
hand side of the unit and the gas inlet is on the
right hand side of the valve.
The gas line connection may be made of rigid
pipe, copper pipe or an approved flex connector.
(If you are using rigid pipe, ensure that the
valve can be removed for servicing.) Since some
municipalities have additional local codes it is
always best to consult with your local authorities
and the CSA B149.1 installation code.
For USA installations follow local codes and/or
the current National Fuel Gas Code, ANSI Z223.1.
When using copper or flex connectors use only
approved fittings. Always provide a union so
that gas lines can be easily disconnected for
servicing. Flare nuts for copper lines and flex
connectors are usually considered to meet this
requirement.
Important: Always check for gas leaks
with a soap and water solution or gas
leak detector. Do not use open flame for
leak testing.
®
P36D-10 Zero Clearance Direct Vent Gas Fireplace
|