VENTING ARRANGEMENTS - VERTICAL TERMINATION

RIGID PIPE SYSTEM
(Propane & Natural Gas)
The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90
vent systems for Propane and Natural Gas.
• Vent must be supported at offsets.
• Firestops are required at each floor level and whenever passing through a wall.
• Maintain clearances to combustibles.
Note: Must use optional rigid pipe adaptor when using rigid vent systems (Part # 510-994).