Changing The Main Fuse - KTM 500 EXC F 2024 Owner's Manual

Table of Contents

Advertisement

15.4

Changing the main fuse

Warning
Fire hazard Incorrect fuses overload the electrical system.
Only use fuses with the required ampere value.
Do not bypass or repair fuses.
Info
The main fuse protects all electrical power consumers of the vehicle. It is located in the starter relay hous-
ing under the seat.
»
Battery voltage: < 9 V
Do not charge the 12-V battery.
Replace the 12-V battery and dispose of the old 12-V
battery properly.
»
If the specifications have been met:
Battery voltage: ≥ 9 V
Connect a battery charger to the 12-V battery. Switch
on the battery charger.
Guideline
Maximum charging volt-
age
Maximum charging cur-
rent
Maximum charging time
Recharge the 12-V bat-
tery regularly when the
motorcycle is not being
used
Ideal charging and stor-
age temperature of the
lithium-ion battery
Battery charger (79629974000)
This battery charger tests whether the 12-V battery
retains its voltage. It is also impossible to overcharge
the 12-V battery with this battery charger. The charging
time may be longer at low temperatures.
This battery charger is only suitable for lithium iron
phosphate batteries. Read the accompanying KTM Pow-
erParts instructions.
Info
Never remove cover
Switch off the battery charger after charging and disconnect
from the 12-V battery.
Finishing work
Install the 12-V battery.
Install the fuel tank.
(
Mount the seat. (
p. 72)
ELECTRICAL SYSTEM 15
14.4 V
3.0 A
12 h
6 months
10 ... 20 °C (50 ...
68 °F)
1
.
(
p. 111)
p. 80)
113

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

500 exc f six days 2024

Table of Contents