Power Regeneration Converter - Mitsubishi Electric MR-J2S B Series Instruction Manual

Servo amplifier
Table of Contents

Advertisement

12. OPTIONS AND AUXILIARY EQUIPMENT
(2) Connection example
NFB
(Note 5)
Power
supply
Note 1. When not using the phase detection terminals, fit the jumpers across RX-R, SX-S and TX-T. If the jumpers remain removed, the
FR-RC will not operate.
2. When using servo amplifiers of 5kW and 7kW, always remove the lead of built-in regenerative resistor connected to P terminal
and C terminal.
3. For the power factor improving reactor (FR-BAL) to be used, refer to POWER REGENERATION CONVERTER FR-RC
INSTRUCTION MANUAL (IB (NA) 67096). When using FR-BAL with the servo amplifier of 11 k to 22 kW, do not use with the
power factor improving reactor (FR-BAL).
4. When using the servo amplifier of 11k to 22kW, make sure to connect P
5. Refer to section 1.3 for the power supply specification.
(Note 3) Power factor improving reactor
FR-BAL
MC
FR-RC
RA2
B C
Servo amplifier
L
11
L
21
L
1
L
2
L
3
VDD
COM
EM1
SG
N
N/
RDY
Ready
SE
R/L
1
S/L
2
T/L
3
RX
R
SX
S
TX
T
Power regeneration
converter FR-RC
Operation ready
EM1
OFF
and P. (Factory-wired.)
1
12 - 18
(Note 2)
C
P
P
1
5m(16.4ft) or less
(Note 4)
P/
A
RDY
B
output
C
Alarm
output
(Note 1)
Phase detection
terminals
ON
MC
MC
SK
B
C