1.2

Combination with converter units and drive units

Combination with power regeneration converter units and drive
units
Selection method
Use the following conditions to select a power regeneration converter unit. By satisfying all the conditions, multiple drive units
can be connected to one power regeneration converter unit. When connecting multiple drive units, arrange them in
descending order of capacity per axis of the drive unit from the right side of the power regeneration converter unit.
• Effective value of total output power of servo motors [kW] ≤ Continuous rating of the MR-CV_ [kW]
• Maximum value of total output power of servo motors [kW] × 1.2 ≤ Instantaneous maximum rating of the MR-CV_ [kW]
• Total unit width of the MR-J5D_ ≤ 1500 mm
MR-CV_
Continuous rating [kW]
Instantaneous maximum rating [kW]
Total unit width of the MR-J5D_
Item
MR-J5D1-_
100G4
Unit width [mm]
60
Selection example
The following information explains how to select a power regeneration converter unit to connect the drive units and servo
motors listed below.
Drive unit
MR-J5D2-700G4
MR-J5D3-200G4
1 INTRODUCTION
10
1.2 Combination with converter units and drive units
11K4
7.5
39
1500 mm or less
200G4
350G4
500G4
Servo motor
HK-ST7024M
HK-ST5024M
HK-ST2024M
HK-ST2024M
HK-ST2024M
18K4
30K4
11
20
60
92
MR-J5D2-_
700G4
100G4
200G4
60
37K4
45K4
55K4
25
25
55
101
125
175
350G4
500G4
700G4
75
75K4
55
180
MR-J5D3-_
100G4
200G4
60