4.15 Connecting the IO Device with DeviceNet

The DeviceNet unit (FCU6-EX871-40) must be mounted in the control unit's extension slot to connect
IO devices with DeviceNet.
Connect the dedicated DeviceNet cable to the DeviceNet unit's terminal block (enclosed).
When setting the parameters in the DeviceNet unit using the configuration software (parameter setting
tool), connect an RS-232C cross cable between the DeviceNet unit and personal computer (PC/AT
compatible unit). The configuration software must be installed in the personal computer at this time.
This unit functions as the DeviceNet master station. Refer to the DeviceNet Specifications (Release
2.0) issued by ODVA (Open DeviceNet Vendor Association) for details on the DeviceNet system.
Control unit
LED1
DeviceNet
connector
DeviceNet
DeviceNet
FG wire
(Note 1)
RS-232C connector for
configuration
RS-232C cross cable
PC/AT compatible unit +
configuration software
CAUTION
Incorrect connections could cause device damage, so always connect the cables to the
designated connectors.
Do not connect or disconnect the connection cable between each unit while the power
is ON.
Separate the signal wire from the drive line/power line when wiring.
4. CONTROL UNIT CONNECTIONS
4.15 Connecting the IO Device with DeviceNet
Tap
(Note 1) Connect the FG wire between the shield terminal on
the DeviceNet terminal block (enclosed) and FG
terminal on the bottom of the control unit.
(Note 2) Labels corresponding to the DeviceNet cable colors
are attached to the DeviceNet unit plate. Match the
cable color with the label color when connecting the
cables to the DeviceNet terminal block (enclosed).
RS-232C cross cable connection
DeviceNet unit
D-sub female connector (9 pin)
2
RXD
3
TXD
4
DTR
6
5
GND
1
7
RTS
8
CTS
9
<Caution> There are open pins on the DeviceNet unit side, but
connections should be made to all pins to eliminate the
cable orientation.
I - 43
Get other manuals https://www.bkmanuals.com
DeviceNet cable
DeviceNet terminal block
(Note 2)
5 (red)
4 (white) CAN_H
3
2 (blue)
1 (black) V-
Label
PC/AT compatible unit
D-sub female connector (9 pin)
2
RXD
3
TXD
4
DTR
6
DSR
5
GND
1
DCD
7
RTS
8
CTS
9
RI
V+
Shield
CAN_L