6.15 Cables

The remote I/O unit cable types include the R300 and R301 cables. The R300 cable has one end cut off,
and the R301 cable is used for connections with the Izumi Denki terminal block BX1F-T40A (Note 1).
The R300-3M and R301-3M cables are available.
If a cable longer than 3m is required, use the CN300 or CS301 connector set.
The R041-3M (one-piece) and R042-3M (two-piece) manual pulse generator cables are available. The
analog input/output cable R031 must be prepared by the user.
Machine control panel,
electric cabinet, etc.
RA
PL
6. CONNECTION OF REMOTE I/O UNIT
6.15 Cables
(Note 1) Izumi Denki I/O terminal BX1F-T40A
R300 cable
R301 cable
Terminal
block
BX1F
-
I
73
Get other manuals https://www.bkmanuals.com
Connector pin correspondence table
DX1
1
A1
3
A2
5
A3
7
A4
9
A5
11
A6
13
A7
15
A8
17
A9
19
A10
21
A11
23
A12
25
A13
27
A14
29
A15
31
A16
33
A17
35
A18
37
A19
39
A20
Terminal
block
DX1
BX1F
2
B1
34
B2
6
B3
8
B4
10
B5
12
B6
14
B7
16
B8
18
B9
20
B10
22
B11
24
B12
26
B13
28
B14
30
B15
32
B16
34
B17
36
B18
38
B19
40
B20