Appendix 9.2 Emc Directives - Mitsubishi Electric MELDAS C6 Maintenance Manual

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

Appendix 9.2 EMC Directives

The EMC Directives largely regulate the following two items.
• Emission ..... Capacity to prevent output of obstructive noise that adversely affects external devices.
• Immunity ..... Capacity not to malfunction due to obstructive noise from external source.
The details of each level are classified below in Table 1.
It is assumed that the Standards and test details required for a machine tool are the same as these.
Class
Name
Radiated noise
Emission
Conductive noise
Static electricity
electrical discharge
Radiation immunity
Burst immunity
Conductive
immunity
Immunity
Power supply
frequency magnetic
field
Power supply dip
(fluctuation)
Surge
APPENDIX 9 EMC INSTALLATION GUIDELINES
Appendix 9.2 EMC Directives
Restriction of electromagnetic noise radiated
through the air
Restriction of electromagnetic noise
discharged from power supply line
Example)
Regulation of withstand level of static
electricity accumulated in human body
Simulation of immunity from digital wireless
telephones
Example)
Regulation of withstand level of noise from
relay or live wire being inserted or removed
Example)
Regulation of withstand level of noise
flowed from power supply wires, etc.
Example)
Regulation of electromagnetic noise of
50/60Hz power supply frequency
Example)
Regulation of power voltage drop
withstand level
Example)
Regulation of withstand level of noise
caused by lightning
I - 105
Get other manuals https://www.bkmanuals.com
Details
EN50081-2
EN61800-3
(Industrial
environment)
EN50082-2
EN61800-3
(Industrial
environment)
EMC
Standard
EN55011
(CLASS:A)
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
IEC61000-4-5

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Meldas c64

Table of Contents