Appendix 7.6 F340 Cable Manufacturing Drawing - Mitsubishi Electric MELDAS C6 Maintenance Manual

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

APPENDIX 7 CABLE MANUFACTURING DRAWINGS

Appendix 7.6 F340 Cable Manufacturing Drawing

Application : External skip signal input (4 points)
Assembly drawing
Cotrol
1 2 3
unit side
Note (2)
Connection diagram
Control
unit side
SKIP0
1
SKIP0*
6
SKIP1
2
SKIP1*
7
SKIP2
3
SKIP2*
8
4
SKIP3
9
SKIP3*
Manufacturing precautions
(1) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used providing
they are compatible with the specifications.
(2) Attach the nameplate (with protective cover stamped with the cable name) in the position
designated in the assembly drawing.
(3) Fold the wire material shield on the control unit side over the sheath, and wrap copper foil tape
over it. Connect to the connector case GND plate.
(4) Stamp the name of each signal on the crimp terminal side mark tube and install.
(5) Insulate the crimp terminals of unused signal wires with vinyl tape, etc.
Appendix 7.6 F340 Cable Manufacturing Drawing
Skip signal input
5
4
F340
F340
Case GND plate
Get other manuals https://www.bkmanuals.com
List of parts used
No.
Part name/type
Connector
1
CDE-9PF
Contact
2
CD-PC-111
Connector case
3
HDE-CTH
Wire material
4
B-22(19)X2SJ-1X9
Crimp terminal
5
V1.25-4
Maximum cable length: 30m
I - 91
Maker
Q'ty
Hirose
1
Electric
Hirose
8
Electric
Hirose
1
Electric
Sumitomo
(4)
Denko
J. S. T
8
Skip signal input
SKIP0
SKIP0*
SKIP1
SKIP1*
SKIP2
SKIP2*
SKIP3
SKIP3*