5.2.3 Connection of Power Supply to 9-type CRT (FCUA-CT100/FCUA-CR10+KB10)

Supply 100VAC to the connector CRT2 on the rear of the CRT, and 24VDC to the connector CR01 on
the rear of the keyboard.
Stabilized power supply
(Prepare separately)
R220 cable
24VDC(+)
0V
FG
FG
<Caution>
Use a two-circuit ON/OFF
switch and always establish a
double-off system.
Terminal block
100VAC~115VAC
(Enclosed with FCUA-CT100/CT120/CR10+KB10)
CAUTION
Separate the signal wire from the drive line/power line when wiring.
Do not apply voltages other than those indicated in this manual on the connector. Doing
so may lead to destruction or damage.
Incorrect connections may damage the devices, so connect the cables to the specified
connectors.
5. CONNECTION OF COMMUNICATION TERMINAL
5.2 Connection of Power Supply
Recommended adaptive connector
(Enclosed with FCUA-CT100/FCUA-CR10+KB10)
Connector : 2-178288-3
Contact
: 1-175218-5 (tin plated) (Tyco Electronics AMP)
Y
CR01
CR06
100VAC
3 2 1
(M4)
R100 cable
I - 51
Get other manuals https://www.bkmanuals.com
1 24VDC(+)
2 0V
3 FG
[FCUA-CT100/CT120/CR10+KB10 rear view]
CR03
CR04
CR02
CR05
CR04-1 cable
Recommended adaptive connector
(Connected to R100 cable)
Connector : 3191-03R1
Contact
CRT
CRT2
CRV
Cable clamp
CRT1
: 1381TL(Morex)