B General - Fetco TBS-122D Users Manual And Operator Instructions

Dual iced tea brewer
Table of Contents

Advertisement

B GENERAL

POSITION
Program Items
B1
Tank Temp.
B2
Brew at Temp.
B3
Batch Temp
Show Tank
B4
Temperature
Units of Measure
B5
TEMPERATURE
Units of Measure
B6
VOLUME
B7
Customer Name
B8
Customer Name
B9
Demo Mode
B10
Eco Mode
Eco Idle Time
B11
(turns on if B10 active)
Eco Idle Temp
B12
(turns on if B10 active)
B13
Filter Life
BREW AT TEMPERATURE DEFINITIONS
DEFAULT: BREW AT TEMP: "ON"
(FACTORY DEFAULT FOR BREWER)
"BREW at TEMP:
-Batch will not start if tank temperature
is below set point.
-Display will show "HEATING"
and hot water tank temperature
The "BREW START" entry buttons will not
illuminate until the hot water tank reaches the
selected temperature.
Notifications shown on screen:
TEXT: HEATINGTank above 87°C/189°F-
will allow brew at low temperature.
Extracted tea flavor may be affected
TEXT: L. HEATTank above 76°C/169°F-
will allow brew at low temperature.
Tea flavor will be noticeably affected
USER SELECTABLE OPTION: BREW AT TEMP: OFF
(Not recommended) Unit will operate at reduced temperature
Allows brewing at any temperature above 169°F/76°C
Go to fetco.com for the latest versions of all information
Brewer Operation Control Settings, Adjust Brew Flow Rate
Factory set Default
Programming Range
200°F-or-93°C
"YES"
OFF
YES
° Fahrenheit
Fahrenheit/Celsius
Ounces
Ounces/Liters/Gallons
Off
(only if above is
Scroll with batch keys
"ON)
OFF
DEMO ON/OFF
Off
1Hr
169°F
OFF
Hot water tank not at
Tank temp
STOP is not lit
& BREW START
buttons not lit.
.
and are disabled
Batch menu
button(s ) will
illuminate and
"READY" will display
on screen when hot
water tank
temperature is at
setpoint
Page 8
Increments
170° to 207°F
1.0°F
77° to 97°C
0.5°C
ON/OFF
YES/NO
ON/OFF
ON/OFF
YES/NO
Oz/L/Gal
NO or YES
A-Z;a-z;0-9
ON/OFF
YES/NO
1-6 hours
1 hour
158-176°F
1 degree
ON/OFF
YES/NO
Chart to correct for altitude for boiling point
[ft]
0
brew temp setpoint.
500
HEATING
1000
160°F
2000
2500
STOP
3000
3500
4000
4500
FETCO
5000
Ready to Brew
5500
STOP
6000
6500
7000
7500
8000
8500
User Guide & Operator instructions
Notes
Chart to correct for
high altitude below
SEE NOTE BELOW
For tea brewing
temperature for A190
To display HW tank
temperature on screen
NOTE: Overwrites
C/F
user settings
(see page 9)
NOTE: Overwrites
user settings
(see page 9)
For name on screen
16 characters total
Demonstrates the controls
for training. Disables all
components in demo mode
If Selected: Lowers hot
water tank temperature after
preset time of inactivity
Time of inactivity to go into
ECO Mode
Temperature that hot water
tank is lowered to
Water filter life is accessed
in G-Counters. This is user
set and will display indicator
to change water filter
in hot water tank water temperature.
Suggested
Boiling
Suggested
[m]
Setting[°F]
point[°F]
Setting[°C]
0
205
212.0
96
152
205
211.0
96
305
200
210.1
93
610
200
208.1
93
762
200
207.2
93
914
200
206.2
93
1067
197
205.3
92
1219
195
204.3
91
1372
194
203.4
90
1524
194
202.4
90
1676
193
201.5
89
1829
192
200.6
89
1981
191
199.6
88
2134
190
198.7
87
2286
188
197.8
86
2438
187
196.9
86
2591
185
196.0
85
P209 REV002 August 2023
Boiling
point [°C]
100.0
99.5
98.9
97.8
97.3
96.8
96.3
95.7
95.2
94.7
94.2
93.6
93.1
92.6
92.1
91.6
91.1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tbs-1221