B General - Fetco CBS-1221 Users Manual And Operator Instructions

Single air pot brewer
Table of Contents

Advertisement

B GENERAL

POSITION
Program Items
B1
Tank Temp.
B2
Brew at Temp.
Units of Measure
B3
TEMPERATURE
Units of Measure
B4
VOLUME
Show Tank
B5
Temperature
BREW AT TEMPERATURE DEFINITIONS
DEFAULT: BREW AT TEMP: "ON"
(FACTORY DEFAULT FOR BREWER)
"BREW at TEMP:
-Batch will not start if tank temperature
is below set point.
-Display will show "HEATING"
and hot water tank temperature
The "BREW START" entry buttons will not
illuminate until the hot water tank reaches the
selected temperature.
Controls allow both sides of dual brewer to
operate if one side has an ongoing brew
started and the second side brew is selected.
Notifications shown on screen:
TEXT: HEATINGTank above 87°C/189°F-
will allow brew at low temperature.
Coffee flavor may be affected
TEXT: L. HEATTank above 76°C/169°F-
will allow brew at low temperature.
Coffee flavor will be noticeably affected
USER SELECTABLE OPTION: BREW AT TEMP: OFF
(Not recommended) Unit will operate at cold temperature
Allows brewing at any temperature above 77°C/170°F
Below 70°C/170°F The red colored ready lights switch turn off
Go to fetco.com for the latest versions of all information
Brewer Operation Control Settings, Adjust Brew Flow Rate
Factory set Default
Programming Range Increments
200°F -or- 93°C
NOTE: Units are in
English by default
"YES"
°F Fahrenheit
Fahrenheit/Celsius
L LITERS
YES
Tank temp
STOP is not lit
BREW START
buttons not lit.
.
and are disabled
Buttons will
illuminate "READY"
when hot water tank
temperature is at
setpoint
Page 6
170° to 207°F
77° to 97°C
ON/OFF
YES/NO
Gallons/Liters
YES/NO
Hot water tank not at
brew temp setpoint.
[ft]
HEATING
160°F
500
STOP
1000
2000
2500
3000
3500
4000
4500
5000
5500
6000
6500
7000
7500
8000
8500
User Guide & Operator instructions
Notes
1.0°F
Chart to correct for
0.5°C
high altitude below
SEE NOTE BELOW
NOTE: Overwrites
C/F
user settings
NOTE: Overwrites
L/Gal
user settings
To display HW tank
temperature on screen
Chart to correct for altitude for boiling point
in tank water temperature.
Suggested
Boiling
Suggested
[m]
Setting[°F]
point[°F]
Setting[°C]
0
0
205
212.0
152
205
211.0
305
200
210.1
610
200
208.1
762
200
207.2
914
200
206.2
1067
197
205.3
1219
195
204.3
1372
194
203.4
1524
194
202.4
1676
193
201.5
1829
192
200.6
1981
191
199.6
2134
190
198.7
2286
188
197.8
2438
187
196.9
2591
185
196.0
P194Re0
November 2020
(see page 9)
(see page 9)
Boiling
point [°C]
96
100.0
96
99.5
93
98.9
93
97.8
93
97.3
93
96.8
92
96.3
91
95.7
90
95.2
90
94.7
89
94.2
89
93.6
88
93.1
87
92.6
86
92.1
86
91.6
85
91.1

Hide quick links: