B General - Fetco CBS-1241 Users Manual And Operator Instructions

Extractor plus brewing system
Table of Contents

Advertisement

B General

POSITION
Program Items
B1
Tank Temp.
B2
Brew at Temp.
Show Tank
B4
Temperature
Units of Measure
B5
TEMPERATURE
Units of Measure
B6
VOLUME
B7
Customer Name
B7
Customer Name
B9
Demo Mode
B10
Eco Mode
B11
Eco Idle Time
B12
Eco Idle Temp
B13
Filter Life
BREW AT TEMPERATURE DEFINITIONS
DEFAULT: BREW AT TEMP: "ON"
(FACTORY DEFAULT FOR BREWER)
"BREW at TEMP:
-Batch will not start if tank temperature
is below set point.
-Display will show "HEATING"
and hot water tank temperature
The "BREW START" entry buttons will not
illuminate until the hot water tank reaches the
selected temperature.
Controls allow both sides of dual brewer to
operate if one side has an ongoing brew
started and the second side brew is selected.
Notifications shown on screen:
TEXT: HEATINGTank above 87°C/189°F-will
allow brew at low temperature.
Coffee flavor may be affected
TEXT: L. HEATTank above 76°C/169°F-will
allow brew at low temperature.
Coffee flavor will be noticeably affected
USER SELECTABLE OPTION: BREW AT TEMP: OFF
(Not recommended) Unit will operate at cold temperature
Allows brewing at any temperature above 77°C/170°F
Below 70°C/170°F The red colored ready lights switch turn off
Go to fetco.com for the latest versions of all information
Brewer Operation Control Settings, Adjust Brew Flow Rate
Factory set Default
Programming Range
200°F-or-93° C
NOTE: Equipment is
Fahrenheit by default
"YES"
YES
° Fahrenheit
Gallons
Gallons/Liter/Ounces
Off
(only if above is "ON)
DEMO ON/OFF
On
1Hr
170°F
OFF
Hot water tank not at
brew temp setpoint.
Tank temp
STOP is not lit
BREW START
buttons not lit.
.
and are disabled
When hot water tank
temperature is at
setpoint. Buttons will
illuminate and
"READY" will be
displayed
Increments
77° to 97°C
0.5°C
170°F to 207°F
1.0°F
ON/OFF
YES/NO
YES/NO
Fahrenheit/Celsius
L/Gal/Oz
NO or YES
Scroll with batch
A-Z;a-z;0-9
keys
ON/OFF
YES/NO
1-6 hours
1 hour
158-176°F
1 degree
ON/OFF
YES/NO
Chart to correct for altitude for boiling point
[ft]
vv
vv
vv
0
500
HEATING
1000
160°F
2000
2500
STOP
STOP
3000
3500
1067
4000
1219
4500
1372
5000
1524
5500
1676
6000
1829
6500
1981
7000
2134
7500
2286
8000
2438
8500
2591
User Guide & Operator instructions
Page 8
Notes
Chart to correct for high
altitude below
SEE NOTE BELOW
To display HW tank
temperature on screen
NOTE: Overwrites user
C/F
settings
(see page 9)
NOTE: Overwrites user
settings
(see page 9)
For name on screen
16 characters total
Demonstrates the controls for
training. Disables all
components in demo mode
If Selected: Lowers hot water
tank temperature after preset
time of inactivity
Time of inactivity to go into
ECO Mode
Temperature that hot water
tank is lowered to when in
ECO Mode
Water filter life is accessed in
G-Counters. This is user set
and will display indicator to
change water filter
in tank water temperature.
Suggested
Boiling
Suggested
[m]
Setting[°F]
point[°F]
Setting[°C]
0
205
212.0
96
152
205
211.0
96
305
200
210.1
93
610
200
208.1
93
762
200
207.2
93
914
200
206.2
93
197
205.3
92
195
204.3
91
194
203.4
90
194
202.4
90
193
201.5
89
192
200.6
89
191
199.6
88
190
198.7
87
188
197.8
86
187
196.9
86
185
196.0
85
P212e0August 2021
Boiling
point [°C]
100.0
99.5
98.9
97.8
97.3
96.8
96.3
95.7
95.2
94.7
94.2
93.6
93.1
92.6
92.1
91.6
91.1