Default setting 1 ( = )
Setting  to  will return parameters to the standard values that were programmed at the factory.
(Refer to 4.2.6)
When  is set,  is displayed for a short time after the settings are configured, and then
disappears. Then the inverter is in standard motor mode. In this case, the trip history data is cleared.
Be aware that the following parameters do not return to the standard factory settings even if = is
set for maintainability. (To initialize all parameters, set =.) 
•  : Meter selection
•  : Meter adjustment gain
•  : Check the region settings selection
•  : Analog/logic input selection (VI terminal)
•  : Sink/source switching
•  : VI voltage input bias
•  : VI voltage input gain
Trip record clear ( = )
Setting  to  initializes the past four sets of recorded error history data.
The parameter does not change.
Cumulative operation time clear ( = )
Setting  to  resets the cumulative operation time to the initial value (zero).
Cumulative operation time clear ( = )
Setting typ to  clears the trips when an  format error occurs. But if the  displayed, call us.
Save user setting parameters ( = )
Setting  to  saves the current settings of all parameters. (Refer to 4.2.7)
Load user setting parameters ( = )
Setting  to  loads parameter settings to (calls up) those saved by setting  to . (Refer to 4.2.7)
By setting  to  or , you can use parameters as your own default parameters.
Cumulative fan operation time record clear ( = )
Setting  to  resets the cumulative operation time to the initial value (zero).
Set this parameter when replacing the cooling fan, and so on
Default setting 2 ( = 1)
Set  to  to return all parameters to their default settings. (See 4.2.6.)
When  is set,  is displayed for a short time after the settings are configured, and then
disappears. Then setup menu  is displayed. After reviewing the setup menu items, make a setup
menu selection. In this case, all parameters are returned to their defaults, and the trip history data is cleared.
(See 3.1.)
•  : Logic output/pulse train output
selection (OUT-NO)
•  : Analog output signal selection
•  : Analog output inclination characteristic
•  : Analog output bias
•  : Factory specific coefficient 6D
•  : Free memo