Ex.4
(1)
3
(2)
(3)
Setting the frequency using external signals, run/stop using external
signals.
Wiring
PO
MCCB
R/L1
*
S/L2
Noise
T/L3
filter
Parameter setting
Title
Command mode selection

Frequency setting mode selection

Operation
Run/stop: ON/OFF input to F-CC, R-CC. (with sink logic)
Frequency setting: VI: Input 0-10Vdc (external potentiometer) or 4-20mAdc to set the frequency.
* Set the voltage/current input of VI in parameter  .
0: Voltage signal input (0-10V)
1: Current signal input (4-20mA)
3: Voltage signal input (0-5V), when the P5 terminal is connected and the external potentiometer is
used
* Single-phase, 200V models only
PA/+
PC/-
U/T1
V/T2
Power circuit
W/T3
F
Control
circuit
R
CC
VI
CC
VI
PP
External potentiometer
(Otherwise, input voltage signal between the terminals VI-CC.)
Function
C-12
E6581595
Motor
IM
Foward signal
Reverse signal
Common
Current signal: 4∼20mA
Voltage signal: 0∼10V / 0∼5V