efesotomasyon.com -Toshiba inverter,drive,servo,plc
E6581595
3) S-shape acceleration/deceleration 2
Motor acceleration torque increases slowly in areas with a small weak magnetic field. Perfect for operation of
high-speed spindles.
Output frequency [Hz]
Output frequency [Hz]
Max. frequency
Max. frequency
Set frequency
Set frequency
Base frequency
Base frequency
0
0
Time
Time [s]
[s]
Actual acceleration time
Actual deceleration time
6
F-44